All-in-one solar charge inverter V11 29
Parameter
no.
Parameter
name
Settings
Description
Beeps while
primary source
is interrupted
[26] ENA
default
Alarm beep is enabled when the status of the main
input source changes
27
Bypass output
when over load
[27] DIS
It is disabled to automatically switch to the Mains
when the inverter is overloaded.
[27] ENA
default
It is enabled to automatically switch to the Mains
when the inverter is overloaded.
28
Max AC charger
current
[28] 60A
default
AC Out 230Vac Setting range 0~60A
29
Split Phase
[29] DIS
default
Supply for industrial frequency transformer (disabled)
[29] ENA
Supply for industrial frequency transformer (enabled)
35
Battery
undervoltage
recovery point
[35] 52V
default
When the battery voltage is under voltage, the
battery voltage needs to recover more than this set
value before the inverter starts the output
36
Max PV charger
current
[36] 60A
default
Max PV charger current. Setting range:
0~60A
(HF4830S60-145)
[36] 80A
default
Max PV charger current. Setting range: 0~80A
37
Battery fully
charged
recovery point
[37] 52V
default
After the battery is fully charged, it needs to be lower
than this set voltage before it can be recharged
38
AC output
voltage setting
(only can be set
in the standby
mode )
[38]230Vac
default
S series model
:230Vac
default
.
Allow to set to 200/208/220/230/240Vac.
The rated output power will be reduced=
(Power Rate)*(Vset/230)