PF6000X
Troubleshooting Guide
ELECTRICAL ERRORS
CAUSE
CORRECTION
Blank screen on PLC but power to other
devices in the control panel
Door switch circuit not making
Press door switch in and check PLC screen
PLC has developed an electrical fault or had a
power spike
Change PLC
Barrier does not run (stays open)
Check inverter is in ready (rdy) mode on display
Power down then back up
Loop detector is faulting or sensing presence
Clear obstacle or reset the detector
Check inverter settings
ACC - 6.0 DEC – 2.0 LSP – 25-40 (Variable)
Barrier staying up in raise position
Access control giving a constant pulse shorten
this
Photo cell batteries (if fitted)
Check that the fitted batteries still have power to
them. They should only be replaced with special
3.6V Lithium-ion batteries made for purpose.
These can be provided by your supplier
Safety Edge
Should be showing 8.2K
Ω
Barrier not going up
Access control may be faulty
Remove and check barrier function via the PLC
Barrier Staying up
Car has driven o ffbefore clearing the loop
Complete cycle by going through the ground
loop
“Stop Circuit Broken” displaying on screen
Circuit Broken
Check Link between I1 & I2
Barrier staying open and not closing
If photo-cells fitted then batteries may have
expired
Check and if needed replace batteries
Faulty loop detector
Check & set or replace faulty unit
Barrier does not have loops fitted or these have
been removed
Call the technical department for assistance the
program/wiring needs to change
Key switch left in open position
Put the switch back into the “Auto” position
Permanent supply/signal to the raise terminals
Check wiring to terminal blocks remove any
access control try again
Barrier programmed for safety only or barrier is
on a timer
Contact your supplier for a program
modifacation chip
Summary of Contents for PF6000X
Page 1: ...PF6000X Automatic Barrier Rev 1 0 Installation Operation Maintenance Manual ...
Page 11: ...PF6000X Handing Change Procedure ...
Page 12: ...PF6000X Handing Change Procedure ...
Page 13: ...PF6000X Handing Change Procedure ...
Page 14: ...PF6000X Barrier Manual Release Procedure ...
Page 15: ...PF6000X Straining Wire Assembly ...
Page 23: ...PF6000X Loop Detector Guide Relay Functionality Diagnostics ...
Page 28: ...PF6000X Safety Edge Setup ...
Page 29: ...PF6000X Safety Edge Setup ...