When a number or letter is shaded this denotes that input is active. So if something below should be normally closed then when shaded this is
in its normal state. If a normally closed input is unshaded then this denotes that the circuit has gone open and the input is active.
For instance if IE is shaded with a box then the photocells are in a normal state and the barrier would lower. If this becomes UN-shaded then
the photocell beam has been blocked so the barrier will no longer lower.
(if you have a separate safety edge module then input just for photocells)
(Door Safety Switch/External Stop Button)
PF6000X
PLC Logic
Menu/Ok
SR2 B121BD
1
2
Q1
1
2
Q2
1
2
Q3
1
2
Q4
+
-
I1
I2 I3 I4 IB
ID
IC
IE
24VDC
24VDC
24VDC
Analog or
IB....IE
Inputs I1...I4
Outputs
Q1...Q4 : Relay 8A
1. Inputs
Input
Polarity
Connected to
Operation when active
I1
Normally Closed
Stop Circuit
Stop Circuit Active
I2
Normally Open
Raise/Open signal
Barrier is getting a PERMANENT open signal
I3
Normally Open
Lower/Close signal
Lowers barrier (Barrier is getting a permanent Close Signal)
I4
Normally Closed
Raise Limit
Barrier arm has reached fully open position. Upper limit switch active
IB
Normally Closed
Loop detector/Safety loop
Detecting vehicle on safety loop. Lowers when vehicle is not detected
IC
Normally Open
Free entry/Free exit loop
Detecting vehicle on free exit/entry loop/ Barrier opens when vehicle present on loop
ID
Normally Closed
Lower limit
Arm has reached fully closed position. Lower limit switch active
IE
Normally Closed
Safety Edge Input /Photocell Input
Photocell Active or Safety Edge Active
2. Outputs
Output:
Polarity:
Connected to:
Operation when active:
Q1
Normally Open
Motor controller open direction
Active to open barrier
Q2
Normally Open
Motor controller close direction
Active to close barrier
Q3
Normally Open
Boom light or Magnetic arm lock
Signal given to accessories
Q4
Normally Open
Flashing beacon/Siren (if installed in
program)
Signal given to accessory if installed in PLC program
The table (bottom) relates to the diagram directly below to help you trouble shoot electrical component errors
Menu/Ok
SR2 B121BD
1
2
Q1
1
2
Q2
1
2
Q3
1
2
Q4
+
-
I1
I2 I3 I4 IB
ID
IC
IE
24VDC
24VDC
24VDC
Analog or
IB....IE
Inputs I1...I4
Outputs
Q1...Q4 : Relay 8A
1.
2.
1
B
234
CDE
RUN LD
SUN 20 JUL
09:36
1234
1234
BCDE
STOP LD
SUN 20 JUL
09:37
1 3
2 4
Input displays
which change
as inputs used
detailed in the
table below.
Example
showing number
I1 and IB input
selected
Showing program in “run mode”
Showing program in “Stop mode”
Output displays
which change
as Outputs used
detailed in the
table below.
Example
showing number
Q1 and Q3
output selected
Date/Time Display
Date/Time Display
Note:
If barriers are set up as a master and slave then see additional wiring info in this section.
!
Summary of Contents for PF6000X
Page 1: ...PF6000X Automatic Barrier Rev 1 0 Installation Operation Maintenance Manual ...
Page 11: ...PF6000X Handing Change Procedure ...
Page 12: ...PF6000X Handing Change Procedure ...
Page 13: ...PF6000X Handing Change Procedure ...
Page 14: ...PF6000X Barrier Manual Release Procedure ...
Page 15: ...PF6000X Straining Wire Assembly ...
Page 23: ...PF6000X Loop Detector Guide Relay Functionality Diagnostics ...
Page 28: ...PF6000X Safety Edge Setup ...
Page 29: ...PF6000X Safety Edge Setup ...