Owner’s Manual With Instructions
Parker Racor Absolute Oil Cleaner Demo Machine
Page | 3
Instruction #New 07202011
Hydraulic oil
Chevron Unax AW 32 #273277 , or equivalent. Capacity approximately 6 quarts /
5.7 liter
Contaminant
Soft C-2A, (carbon black)
Hose, 5/8”
Clear 5046K14 McMaster Carr
Hose, 5/32”
Clear contaminant line
Set up before operation
1. Make sure the full-flow filter is tight on clear head. Hand-tighten only, do not over tighten.
2. Remove the lid and make sure there is an element in the bypass filter housing. Make sure the
seal is properly seated on main housing and install lid. Place lid on housing and hand tighten the
T-handle until it secures the cover on to the seal.
3. Remove the 4 thumb screws that hold the tank cover in place. Slide the tank cover forward until
it clears the complete unit and set aside.