13. When the fluid in the plastic tank has reached the level of the center flow port between the
plastic tank stop the pump.
14. Locate the brass valve which is forward of the fill port in the storage tank and rotate 90
⁰
counter
clockwise until it stops. This will be in the run position as shown in the photo.
15. With the pump running turn the filter selection valve handle to the full-flow filter. Once the fluid
has filled the element it will flow into the plastic tank. Continue running for a few minutes to
purge the air from the filter.