background image

Owner’s Manual With Instructions

Parker Racor Absolute Oil Cleaner Demo Machine

Page | 5

Instruction #New 07202011

9. Plug in the demo machine to 120v A/C power.

10. Rotate the filter selection valve in the front of the demo machine to the Absolute Filter.

11. Locate the on off switch in the back of the machine and lift the switch to the on position.

12. Monitor the fluid being pumped from the storage tank into the plastic tank. As it rises in the

tank it will flow from the right side into the left portion of the tank.

Summary of Contents for Racor Absolute Series

Page 1: ...u are facing the Demo Machine When lifting the unit always lift from under the frame Do not attempt to lift using the acrylic filter head Damage to the unit will result Tools required 5 8 625 allen wr...

Page 2: ...micron filtration ability depending on the element chosen The flow of the lube oil is in an axial direction Demo Machine Components Bypass oil cleaner pump motor filter pressure gauge Contaminant tan...

Page 3: ...t line Set up before operation 1 Make sure the full flow filter is tight on clear head Hand tighten only do not over tighten 2 Remove the lid and make sure there is an element in the bypass filter hou...

Page 4: ...ank to just below the plug opening This will require approximately 6 quarts 5 7 liter of fluid 6 Replace the tank fill port plug and tighten until the o ring is seated 7 Locate the brass valve forward...

Page 5: ...10 Rotate the filter selection valve in the front of the demo machine to the Absolute Filter 11 Locate the on off switch in the back of the machine and lift the switch to the on position 12 Monitor t...

Page 6: ...op the pump 14 Locate the brass valve which is forward of the fill port in the storage tank and rotate 90 counter clockwise until it stops This will be in the run position as shown in the photo 15 Wit...

Page 7: ...ump becomes noisy and air bubbles are visible in the clear lines then add fluid to the storage tank This can be done while operating the pump Add only what is necessary to stop the air bubbles 19 Repl...

Page 8: ...ver down ONE time to inject the black contaminant Multiple tests may be able to be run after clean up due to an accumulation of Soft C that stays on the bottom of the tank After fluid is cleaned simpl...

Page 9: ...ed 8 Start the pump and watch the right side of the plastic tank as the contaminant flows from the full flow into the right side of the plastic tank and in a short time both sides of the plastic tank...

Page 10: ...ar Note that if too much soft C is injected the clean up will take longer 12 Continue running the pump motors until both tanks are as clear as when demonstration began 13 This concludes the demonstrat...

Page 11: ...h the filter filters and into the right side tank Continue switching from Absolute to full flow filter until all of the fluid is removed from both tank chambers 4 Note some fluid will remain in the cl...

Page 12: ...nt clears the housing wrap the plastic bag around the element and turn upright with the bag opening towards you Tie off the plastic bag and properly discard the dirty element according to environmenta...

Page 13: ...ar tank chamber 7 Stop the pump motor Servicing The Spin on Cartridge Element 1 If the element is too tight to remove by hand a strap wrench may be used Rotate the element counter clockwise 2 A plasti...

Page 14: ...ill result 5 Turn the filter selector valve handle to Full Flow Filter Turn on the pump motor and operate until fluid is visible flowing into the clear tank chamber Pressure Gauge A clean Absolute Byp...

Page 15: ...Owner s Manual With Instructions Parker Racor Absolute Oil Cleaner Demo Machine Page 15 Instruction New 07202011...

Reviews: