27
Hand Pump Setup
1. With the hand pump on a flat and stable work surface,
unlatch the pump’s handle locking hook from the hoop.
2. Remove all dust caps from the hose, tool and pump
quick connects.
3. Connect the pressure gauge tee to the pump’s hydraulic
outlet using the quick connect for added safety and
better control (Figure 30).
4. Connect the hose to the downstream side of the
pressure gauge tee using the quick connect (Figure 31).
5. Connect the downstream side of the hose to the tool’s
hydraulic inlet using the quick connect.
6. Check all system fittings and connections to be sure they
are tight and leak free.
7. Turn the mode wheel at the rear of the pump from
‘CLOSE’ to ‘OPEN’ (Figure 32) and remove the mode
wheel from the pump and (Figure 33), the safety chain
will ensure that the mode wheel is not misplaced.
8. The pump should always be handled with care, especially
when the pump mode wheel has been removed as this
provides a leak path for the hydraulic oil if the pump is
not kept upright.
NOTE:
Ensure that the quick links provided are fastened
between the hose containment hoops and mounting
bracket (there are 2 quick links for each end of the hose)
(Figure 29).
Hand Operated Pump (HP
)
Part Number:
PH-HP
Weight:
9 lbs (4 Kg)
Reference Manual
Document Number L1329 Rev B (Instruction Sheet)
Figure 30
Figure 31
Figure 32
Figure 33