38
Figure 62
Figure 63 top shaft removed
Figure 64
Complex Tube Runs with Tri-Tool
®
In order to facilitate the assembly of complex tube runs the Tri-Tool’s top shaft can be temporarily removed from the tool
to provide access.
1. Use a pair of 30mm spanners, to hold the head of the top shaft while loosening the shaft nut. Remove the nut from the
top shaft (Figure 62).
2. The top shaft can now slide out of the tool (Figure 63).
3. There is now access to install the complex tube run into the Tri-Tool
®
.
4. Re-install the top shaft back into tool and tighten the nut onto the shaft before use.
Warning: Tri-Tool
®
should never be used with the upper shaft removed. This will result in uneven loading of the tool (Figure
64).