➁
Installation • OEM750
12
7. Connect a 24VDC - 75VDC power supply to VDC+ and VDC-, as shown in the
next drawing.
VDC+
GND
(RESERVED)
GND
+75VDC @ 2.7A
GND
POWER
OEM300
POWER
MODULE
TYPICAL
POWER
SUPPLY
7
5
0
DR
IV
E
7
5
0
DR
IVE
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
PWR/FLT
7
5
0
DR
IV
E
7
5
0
DR
IVE
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
PWR/FLT
Power Supply Connections
CAUTION
Do not reverse VDC+ and VDC-. Reversing these connections can seriously
damage the drive.
If you are testing an OEM750 with a separate indexer, or an OEM750X, skip
Step 8 below, and proceed to one of the next two sections.
The next drawing shows the complete OEM750 test configuration with a motor and
an OEM300 Power Module.
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
PWR/FLT
OEM
series
!
7
5
0
D
RIV
E
7
5
0
D
RIVE
Compumotor
OEM
series
M
O D U L E
PO
WER
AC
AC
EARTH
*INSTALL JUMPER FOR 90-132 VAC 50/60 Hz
REMOVE JUMPER FOR 180-265 VAC 50/60 Hz
POWER
GND
+75VDC @ 2.7A
GND
(RESERVED)
DANGER
HIGH
VOLTAGE
DANGER
HIGH
VOLTAGE
USE ONLY
INSULATED WIRE
FOR JUMPER*
Power Supply
Motor
AC
Power
OEM Drive
Test Configuration with OEM750
8. Apply power. The drive’s green POWER LED should be on. If the red FAULT LED
is on, consult
Chapter 4, Troubleshooting. After verifying that the motor moves
clockwise and counterclockwise, turn off power.
• Disconnect cables and resistor.
• Remove cover.
• Turn DIP SW3-#3
on to disable the automatic test function.
• Replace cover.
Summary of Contents for OEM750