➁
Installation • OEM750
38
5.000 (127.00)
1.287
(32.69)
4.650 (118.11)
0.175
(4.45)
0.175
(4.45)
2.000
(50.80)
2.100
(53.34)
0.200 (5.08)
0.450 (11.43)
4.650 (118.11)
1.175
(29.85)
0.200
(5.08)
2x Ø0.187 (4.75) Thru
2x #8-32 UNC-2B
Thru One Fin
2x #8-32 UNC-2B Thru
0.637 (16.18)
OEM-HS1 Dimensions
You can mount the drive in two different configurations with
the OEM-HS1. One is a
minimum area
configuration—it uses
the least amount of panel area. The other is a
minimum depth
configuration.
Panel layout for minimum area is shown in the next figure.
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
PWR/FLT
OEM
series
!
7
5
0
D
RIV
E
7
5
0
D
RIVE
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
PWR/FLT
OEM
series
!
7
5
0
D
RIV
E
7
5
0
D
RIVE
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
PWR/FLT
OEM
series
!
7
5
0
D
RIV
E
7
5
0
D
RIVE
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
PWR/FLT
OEM
series
!
7
5
0
D
RIV
E
7
5
0
D
RIVE
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
PWR/FLT
7
5
0
D
RIV
E
7
5
0
D
R
IV
E
OEM
series
!
0 . 5 ( 1 2 . 7 )
4 . 6 5
( 1 1 8 . 1 )
2 . 3 5
( 5 9 . 7 )
2 ( 5 0 . 8 )
2 . 5
( 6 3 . 5 )
M i n i m u m
Dimensions in
inches (millimeters)
OEM-HS1 Minimum Area Panel Layout
Summary of Contents for OEM750
Page 64: ... Tuning Specifications OEM750 56 ...
Page 90: ...EMC INSTALLATION GUIDE OEM750 OEM750X 82 ...
Page 94: ...INDEX OEM750 86 ...