Disassembly & Inspection
Service Manual
HTG Series Integrated Hydrostatic Transmission
HY13-1528-001-M1/US—HTG Series Service Manual
Disassembly and Inspection
Step
Instruction
Illustration
Remove the rotor set.
Remove section seal from
bottom of rotor set.
1. Rotate rotor set over.
2. Remove the section seal from the
bottom of the rotor set.
Remove the wear plate.
Remove the thrust bearing from
the motor housing.
Add coupling shaft alignment
mark.
It may be necessary to use a flat head
screwdriver in order to lift out the thrust
bearing.
1. The surface must be clean of all oil so
the marks will adhere to the housing
body.
2. Make marks on the coupling shaft in line
with mark on drive link for alignment on
reassembly.