background image

Parker Hannifin S.p.A. – S.B.C. Division 

 

quick installation guide Hi-drive 

 
 

Page 2 of 12 

 

IMPORTANT INFORMATION 

The product Hi-drive, described in this handbook, doesn’t contain accessible parts to the 

customer, to open it or to try to approach the inner components could cause an irreparable  

fault. Some internal circuits are subject to voltages that could create serious hazards for 

people and even be lethal. It is prohibited to approach and/or to violate whichever part of the converter; that 

would involve also the immediate invalidation of the warranty (of one year). 

 

The user shall be responsible for ensuring that installation is done in accordance with the 

applicable Work Safety regulations.: the breach could cause to damages to things and/or 

persons.  

The customer must study with attention the contents of the present manual before the installation/use. The 

installation, the start up and the maintenance are permitted exclusively to persons capable, trained and qualified 

to use of industrial electronic equipment. These persons must be acquaintance of electric/mechanical risk 

associates to products for control the motion connected to mains power. 

 

High equipment to performance for the control like the Hi-drive, is able to produce to 

movements many expresses to forces high. 

Unexpected or unsuspected  movements could be taken place especially during the development of control 

programs: to preview the opportune emergencies and don’t touch the parts of the machine in motion. 

The Hi-drive must be installed in a protected atmosphere. Before using whichever type of drive or motor it is 

important to analyze to all aspects of the application verifying the characteristics on catalogues currents. The 

user is the only responsible for the final decision approximately the system and components to use. 

Parker Hannifin –S.B.C. Division declines every responsibility deriving from an use of the product not in 

compliance with the instruction described in the present manual. 

 

High leakage current! Risk of electric shock! 

Leakage current exceeds 3.5mA.  

Before switching on power for electrical units, all housing and motor must be permanently grounded according 

to the connection diagram. This applies even for brief tests. Use a copper conductor with at least 10mm

cross 

section over its entire course for the protective connection (PE)! European countries: see EN61800-5-1, section 

4.2.5.4.2. USA: see National Electrical Codes (NEC, National Electrical Manufacturers Association (NEMA), 

and local bulging codes. The user of this equipment must maintain the above noted instructions at all times. 

 

Do not touch the surfaces of the mechanism when this is operating or afterwards, because 

the temperatures of some surfaces could touch 85°C (185°F). 

 

The present user’s manual refers to the version standard of the converter. 

The information contained in this handbook, included technical methods and described concepts are owners of 

Parker Hannifin – S.B.C. Division – EME Division and its dealership s and cannot be copier or be used without 

expressed authorization. Parker Hannifin S.B.C. Division engages itself to a constant modernization of the own 

products and the right is reserved to modify anytime produced and manual of use without warning obligation. 

No part of this manual can be reproduced in whichever shape without authorization of Parker Hannifin S.B.C. 

Division. 

 

 
Upon request, Parker Hannifin S.p.A. Divisione S.B.C.offers training courses.

 

 
THIS QUICK INSTALLATION GUIDE REFERS TO THE STANDARD PRODUCT AND DOES NOT REPLACE 
THE MORE COMPLETE VERSION OF THE OPERATOR'S MANUAL. BEFORE USING THE PRODUCT, 
ALWAYS CAREFULLY READ THE COMPLETE OPERATOR'S MANUAL, A COPY OF WHICH IS AVAILABLE 
ON THE CD-ROM ATTACHED TO THE SUPPLY. PARKER HANNIFIN SpA S.B.C. DIVISION DISCLAIMS ALL 
LIABILITY FOR ANY TYPE OF DAMAGE DERIVING FROM INAPPROPRIATE PRODUCT USE. 

 

Conformity to EMC standards 

Immunity:  
EN50082-1* / EN61000-6-2 

 

Basic immunity specifications  

IEC1000-4-2 

 

 

 

level 3  Immunity for electrostatic charge  

IEC1000-4-3 

   level 

Immunity 

for 

electromagnetic 

field 

 

IEC1000-4-4 

 

 

 

level 4  Immunity for fast transmission burst  

Compatibility: 

EN50081-1* / EN61000-6-4 

 

Basic specifications for radio interference  

EN55011 group 1, class A  

 

Limits of measurement for radio interference  

EN55011 group 1, class B* 

 

Limits of measurement for radio interference 

 

Safety 

Safety 

regulation 

   EN50178 

Low voltage regulation  

 

 

73/23/CEE modified by 93/68/CEE 

Applied 

regulation   EN60204-1 

* Conformity to the residential or industrial environment depends on the installation.

 

The performance of “Hi-drive” converter is guaranteed only with synchronous motors with permanent magnets MB 

and SMB Series that have been manufactured by us.  

I

I

M

M

P

P

O

O

R

R

T

T

A

A

N

N

T

T

W

W

A

A

R

R

N

N

I

I

N

N

G

G

 

 

I

I

M

M

P

P

O

O

R

R

T

T

A

A

N

N

T

T

W

W

A

A

R

R

N

N

I

I

N

N

G

G

 

 

I

I

M

M

P

P

O

O

R

R

T

T

A

A

N

N

T

T

Summary of Contents for Hi-drive

Page 1: ...Hi drive Quick installation guide rev 0 November 2004 software rel 0...

Page 2: ...or the protective connection PE European countries see EN61800 5 1 section 4 2 5 4 2 USA see National Electrical Codes NEC National Electrical Manufacturers Association NEMA and local bulging codes Th...

Page 3: ...wer Pout W See diagrams Overvoltage cutout OV Vovl V 870 Undervoltage cutout UV Vund V 70 2 Vmains CONTROL D C power supply Vcc V 24 0 10 Maximum ripple Vcc ripple V Do not exceed range Max power inpu...

Page 4: ...ir entering the converter must not come from or pass through other heat source parts Fit a suitable ventilation filter inside the switchboard 2 3 DIMENSION size HID2 5 8 HID16 25 A 87mm 122mm Measurem...

Page 5: ...ype HID2 HID5 HID8 HID16 HID25 AC mains three fuses Bussmann FWP10A14F Ferraz Shawmut A70P10 1 Bussmann FWP20A14F Ferraz Shawmut A70P20 1 Bussmann FWP30A14F Ferraz Shawmut A70P30 1 Bussmann FWP 50B Fe...

Page 6: ...drive is in RUN mode flashing with interval between the 2 series of flashes the converter is disabled and an alarm has tripped the tripped alarm can be identified by counting the number of flashes be...

Page 7: ...on 6 EIN C 7 N C 7 0VF 8 N C 8 SHIELD 9 0V F 9 5V F X10 encoder output DB9 male X11 CAN DB9 male 1 EOUT A 1 N C 2 EOUT A 2 CANL 3 EOUT B 3 GND CAN 4 EOUT B 4 Reserved 5 EOUT C 5 SHIELD 6 EOUT C 6 Rese...

Page 8: ...Before entering the motor data parameter Pr31 must be defined write 0 for brushless motor default or 1 for asynchronous motor 7 Resolver When the resolver is connected do not use the Less Wiring enc...

Page 9: ...open loop is regulated To the in encoder connector a fixed isolated voltage of 5V is available 8 1 Encoder connection Refer to the diagrams in the Operator s Manual at website www sbcelettronica com...

Page 10: ...Connect the motor to the converter carefully following the manual diagrams 2 Make sure the converter is disabled 3 Start the converter 4 Make sure no alarm has tripped 5 Set the analogue reference at...

Page 11: ...ion see PicoPLC program 8 Auxiliary alarm Depends on application see PicoPLC program 10 Check sum PLC Set the default parameters save switch back on and reprogramme the drive 11 Check sum param Set th...

Page 12: ...MI HI 00 11 04 EN...

Reviews: