quick installation guide Hi-drive 

 
 

Page 6 of 12 

 

 

3.3  Connector layout  

 

 

 

 

(*) 

The yellow and green LEDs are active if, when the drive supply is connected (24Vdc), the drive 

electronics is operating. 

The red LED, called “STATUS” provides a series of information on the state of the converter: 

off

 the converter is disabled without active alarms. 

on

 the converter is enabled: the drive is in RUN mode 

flashing with interval between the 2 series of flashes,

 the converter is disabled and an 

alarm has tripped; the tripped alarm can be identified by counting the number of flashes 

between two intervals. 

Continuous fast flashing

 indicates the command I

2

t is active, the converter remains 

enabled. 

I

I

M

M

P

P

O

O

R

R

T

T

A

A

N

N

T

T

 

I

I

M

M

P

P

O

O

R

R

T

T

A

A

N

N

T

T

 

X5 

X6 

X3 

brake

X4 

X7 

X8 

X9 

X10 

X11

X2 

motor

X1 –

mains 

Status Led (*)

Hi 

drive 

Lower panel 

Module Display/Keypad

(optional) 

Top panel 

Power terminal (top 
panel) 

otherwise

“MOTIONWIZ” 

on CD-Rom enclosed in stock 

MAINS 

MOTOR 

PARKING BRAKE 

Summary of Contents for Hi-drive

Page 1: ...Hi drive Quick installation guide rev 0 November 2004 software rel 0...

Page 2: ...or the protective connection PE European countries see EN61800 5 1 section 4 2 5 4 2 USA see National Electrical Codes NEC National Electrical Manufacturers Association NEMA and local bulging codes Th...

Page 3: ...wer Pout W See diagrams Overvoltage cutout OV Vovl V 870 Undervoltage cutout UV Vund V 70 2 Vmains CONTROL D C power supply Vcc V 24 0 10 Maximum ripple Vcc ripple V Do not exceed range Max power inpu...

Page 4: ...ir entering the converter must not come from or pass through other heat source parts Fit a suitable ventilation filter inside the switchboard 2 3 DIMENSION size HID2 5 8 HID16 25 A 87mm 122mm Measurem...

Page 5: ...ype HID2 HID5 HID8 HID16 HID25 AC mains three fuses Bussmann FWP10A14F Ferraz Shawmut A70P10 1 Bussmann FWP20A14F Ferraz Shawmut A70P20 1 Bussmann FWP30A14F Ferraz Shawmut A70P30 1 Bussmann FWP 50B Fe...

Page 6: ...drive is in RUN mode flashing with interval between the 2 series of flashes the converter is disabled and an alarm has tripped the tripped alarm can be identified by counting the number of flashes be...

Page 7: ...on 6 EIN C 7 N C 7 0VF 8 N C 8 SHIELD 9 0V F 9 5V F X10 encoder output DB9 male X11 CAN DB9 male 1 EOUT A 1 N C 2 EOUT A 2 CANL 3 EOUT B 3 GND CAN 4 EOUT B 4 Reserved 5 EOUT C 5 SHIELD 6 EOUT C 6 Rese...

Page 8: ...Before entering the motor data parameter Pr31 must be defined write 0 for brushless motor default or 1 for asynchronous motor 7 Resolver When the resolver is connected do not use the Less Wiring enc...

Page 9: ...open loop is regulated To the in encoder connector a fixed isolated voltage of 5V is available 8 1 Encoder connection Refer to the diagrams in the Operator s Manual at website www sbcelettronica com...

Page 10: ...Connect the motor to the converter carefully following the manual diagrams 2 Make sure the converter is disabled 3 Start the converter 4 Make sure no alarm has tripped 5 Set the analogue reference at...

Page 11: ...ion see PicoPLC program 8 Auxiliary alarm Depends on application see PicoPLC program 10 Check sum PLC Set the default parameters save switch back on and reprogramme the drive 11 Check sum param Set th...

Page 12: ...MI HI 00 11 04 EN...