4. CiA 402 Drive Profile
37
4.2
Error Code
Once Error generates at Controller (Sense Fault signal), changed to ‘Fault reaction active’ status. Under Fault /
Fault reaction active status, types of error can be checked by Error code (603Fh).
Indicated Error codes are as follows
Error code
External
Indication
1
Status
Description
Hex / Dec
0x7500 / 29952
E-500
EtherCAT Communication
Error
Error generated at EtherCAT
Communication.
0xFF01 / 65281
E-001
Over Current Error
The current through power devices in
inverter exceeds the limit value.
0xFF02 / 65282
E-002
Over Speed Error
Motor speed exceed 3000[rpm].
0xFF03 / 65283
E-003
Position Tracking Error
Position error value is higher than set
value (Following error window (6065h)).
0xFF04 / 65284
E-004
Over Load Error
The motor is continuously operated more
than 5 second under a load exceeding the Max.
torque of motor.
0xFF05 / 65285
E-005
Over Temperature Error
Inside temperature of drive exceeds 55
℃
.
0xFF06 / 65286
E-006
Over Regenerated
Voltage Error
Motor Back-EMF is higher than limit
value.
0xFF07 / 65287
E-007
Motor Connection Error
Abnormal connection between drive and
motor.
0xFF08 / 65288
E-008
Encoder Connection
Error
Abnormal connection between drive and
encoder.
0xFF09 / 65289
E-009
Motor Voltage Error
Input voltage for motor is lower than
limit value.
0xFF0A / 65290
E-010
In-position Error
After operation is finished, position
error (over 1) generated more than 3 seconds.
0xFF0E / 65294
E-014
Input Voltage Error
Input voltage is exceeds setting value.
0xFF0F / 65295
E-015
Position Overflow Error
Position error value is higher than
given value after completion of position movement
command.
0xFF31 / 65329
E-049
Drive Alarm
Generated Extra alarms generated from
drive.
0xFF32 / 65330
E-050
Internal communication
error of drive
Communication error from internal
components of drive generated.
0xFF33 / 65331
E-051
Torque enable Failure
Torque Enable command of drive failed.
0xFF3C / 65340
E-060
Torque enable Sense
Torque Enable response sensing of drive
failed.
0xFF64 / 65380
E-100
ROM Initialization
Error
EEPROM is blank status.
0xFF65 / 65381
E-101
ROM Initialization
Error
Check sum of EEPROM is not matched.
0xFF6E / 65390
E-110
ROM Reading Error
Error generated during EEPROM reading.
0xFF79 / 65401
E-121
ROM Writing Error
Error generated during EEPROM writing.
0xFF7A / 65402
E-122
ROM Writing Error
Error generated during EEPROM writing.
0xFF7B / 65403
E-123
ROM Writing Error
Error generated during EEPROM writing.
0xFF7C / 65404
E-124
ROM Writing Error
Error generated during EEPROM writing.
Table 4.5: Error code Lists
1
Two 7-Segment at the front side of product indicates Error code information.
Summary of Contents for ECL E Series
Page 6: ...Introduction Before Operation 6 ...
Page 8: ...Chapter 1 Product Specification 10 ...
Page 9: ...11 1 1 Part Numbering ...
Page 10: ......
Page 11: ...13 1 2 Product Dimension Figure 1 3 Dimensions ...
Page 14: ...Chapter 2 Installation 16 ...
Page 16: ...2 2 System Configuration EtherCAT Cable Figure 2 1 System Configuration Diagram ...
Page 17: ...2 3 External Wiring Diagram ...
Page 18: ......
Page 24: ... Less than 30V of supplyvoltage Less than 15mA of current flow ...
Page 26: ...Chapter 3 EtherCAT Communication ...
Page 27: ... 26 ...
Page 28: ......
Page 36: ...Chapter 4 CiA 402 Drive Profile ...
Page 37: ... 34 ...
Page 38: ......
Page 52: ...Please refer to drive status control for the rest of bits ...
Page 66: ...Chapter 5 Operataion ...
Page 67: ... 59 ...
Page 72: ...Chapter 6 EtherCAT Object Dictionary ...
Page 73: ... 63 ...
Page 82: ......
Page 89: ...6 EtherCAT Object Dictionary 77 6061h 0 Mode of operation display I8 RO No Tx PDO ...
Page 107: ...6 EtherCAT Object Dictionary ...