3.2.3
Module
With selection of Module, possible to set pre-assigned PDO Mapping and assign correspondent PDO Mapping at
SyncManager.
Module provided from controller is as below.
Module Set
Name
Rx PDO Assign
Tx PDO Assign
119800h
csp - axis : Axis only supports csp
1600h
1A00h
219800h
Axis (Normal) : dynamic select operation mode
1601h
1A01h
‘csp - axis’ is Module for Cyclic synchronous Position Mode. Mode of operation is basically set as 8 and Synchronization
selects DC Mode as a basic.
‘Axis (Normal)’ can freely select Mode. PDO Mapping can be modified according to requirements.
Summary of Contents for ECL E Series
Page 6: ...Introduction Before Operation 6 ...
Page 8: ...Chapter 1 Product Specification 10 ...
Page 9: ...11 1 1 Part Numbering ...
Page 10: ......
Page 11: ...13 1 2 Product Dimension Figure 1 3 Dimensions ...
Page 14: ...Chapter 2 Installation 16 ...
Page 16: ...2 2 System Configuration EtherCAT Cable Figure 2 1 System Configuration Diagram ...
Page 17: ...2 3 External Wiring Diagram ...
Page 18: ......
Page 24: ... Less than 30V of supplyvoltage Less than 15mA of current flow ...
Page 26: ...Chapter 3 EtherCAT Communication ...
Page 27: ... 26 ...
Page 28: ......
Page 36: ...Chapter 4 CiA 402 Drive Profile ...
Page 37: ... 34 ...
Page 38: ......
Page 52: ...Please refer to drive status control for the rest of bits ...
Page 66: ...Chapter 5 Operataion ...
Page 67: ... 59 ...
Page 72: ...Chapter 6 EtherCAT Object Dictionary ...
Page 73: ... 63 ...
Page 82: ......
Page 89: ...6 EtherCAT Object Dictionary 77 6061h 0 Mode of operation display I8 RO No Tx PDO ...
Page 107: ...6 EtherCAT Object Dictionary ...