15
DTX10 - DTX80 USER GUIDE
3.
Catch desiccant in suitable container. Close drain ports and open top fill ports.
4.
Refill with recommended type, size and quantity of desiccant. Wrap sides of the
chambers while filling so desiccant will pack tightly. Some settling may be required to fit
specified amount in tank. One tank size may be used for multiple models, do not be
concerned if tank is not full.
5.
Consult Material Safety Data Sheet and all applicable regulations for disposal of
desiccant. Disposal of desiccant contaminated with oil or other substance may require
different procedures than desiccant replaced strictly due to aging.
NOTE:
Use only manufacturer supplied desiccant which is a high capacity, high quality desiccant
designed and sized for the dryers.
9.2
Inlet and Exhaust Valve Repair
1.
Shutdown the dryer as described in this manual. Remove pressure from the dryer Make
certain there are no “pockets” of pressure isolated by various valves. Open the bleed
valve on the bottom of the control air filter bowl.
2.
Loosen the compression fitting attaching the control tubing to the valve body. Carefully
move the tubing aside.
3.
Disassemble valve to clean or repair. Repair kits are available for most valves.
4.
Reassembly is reverse of disassembly. Replace all O-rings, gaskets and components.