- 15 -
Settings Menu - User Settings
Press the SETTINGS key to cycle thru the user settings
Setting
Description
Setting
User Settings
Default
Settings
TARGET DEW POINT?
38
o
F
36 thru 50
o
F
DRAIN
DURATION?
2 secs
1 thru 30 seconds
DRAIN CYCLE?
60 mins
0 thru 60 minutes
MAX CONDENSER TEMP? 100°F
0 thru 125°F
MAX INLET TEMP?
101°F
0 thru 125°F
TEMPERATURE UNITS? °F
°F, °C
PRESSURE UNITS?
psi
psi, kPa, bars
NETWORK ADDRESS? 1
1 thru 247
Changing the User Settings
Setting
Description
Setting,
Use the UP and DOWN keys to change the setting
Press the SETTINGS key when finished
Select YES or NO to confirm
YES selected, store setting
NO selected, restore previous setting
TARGET DEW POINT?
36°F
TARGET DEW POINT?
36°F
TARGET DEW POINT?
ARE YOU SURE?
New Setting Saved
Setting NOT Saved!