I. PRINCIPLE OF OPERATION 

 

The purpose of the Aprilaire

® 

Dehumidifier is to keep humidity in the house at 

acceptable limits to reduce the unwanted effects of high humidity. The 

dehumidifier measures the condition of the house air to decide when to run. 

 

II. OPERATING INSTRUCTIONS 

 

There are three adjustable settings: the dryness setting, the air cycle period 

and the air cycle time within that period. The dehumidifier can be set from “1” or 

“LESS DRY” to “7” or “MORE DRY” based on desired comfort level. Most 

installations should be initially set to the “3” or “NORMAL” setting; however this 

can be adjusted to your individual needs. 

 

1. ADJUSTING THE DEHUMIDIFIER SET POINT 

 

Use the main control knob (Figure 1) on 

the outside of the unit to set the 

dehumidifier dryness setting. Start with a 

“NORMAL” setting for most installations. 

Moving the knob clockwise to “MORE 

DRY” will make conditions drier. Moving 

the knob toward “LESS DRY”

 

allows for 

higher moisture levels. 

 

Based on the thermostat set point, use the 

following table to determine the control 

knob setting to reach the desired RH value. The dehumidifier will work to achieve 

these values. 

 

 

IV. MAINTENANCE 

 

AIR FILTER 

 

Under normal circumstances, the filter in the dehumidifier should be cleaned or 

replaced once a year. A clean filter is necessary to prevent damage to the 

dehumidifier and allow it to function at full capacity. To remove the filter, first 

unplug or disconnect power to the dehumidifier, then remove the air filter via the 

access panel on the side of the dehumidifier. To clean, flush with warm water and 

detergent solution. After a clean or new filter is reinstalled, replace the access 

panel and reconnect power to the dehumidifier. The replacement filter for the 

dehumidifier is Model 4510 and is available from your installing contractor or from 

most other HVAC contractors in your area. 

 

DRAIN 

 

The drain trap or outlet should be checked and cleaned of debris annually. 

Flush it with water under pressure to ensure opening is clear. 

%RH (± 5%) based on Control Knob Setting and Indoor Temperature 

Control Knob 

Indoor Temperature(°F) 

Setting 

65 

70 

75 

80 

1 - “LESS DRY” 

 

84% 

71% 

60% 

86% 

73% 

61% 

52% 

3 - “NORMAL” 

74% 

63% 

53% 

45% 

64% 

54% 

45% 

39% 

55% 

46% 

39% 

33% 

47% 

39% 

33% 

28% 

7 - “MORE DRY” 

40% 

34% 

28% 

24% 

 

NOTES: 

1.  %RH values are ±5% and are to be 

used as a GUIDE ONLY for initial set-

up. 

2.  Indoor Temperature is measured at 

the inlet to the Model 1700.

 

EXAMPLE: At an indoor 

temperature of 75°F with a 

dehumidifier control knob setting 

of 3 - NORMAL, the dehumidifier 

will work to achieve an RH value 

of 53%.

 