Parker Hannifin
There are two versions defined for Header Code 0 based on
Secondary Master Flag Bit Index 5, Enable Rapid Move Modes.
The default-disabled mode for this flag (Secondary Master Flag Bit
Index 5 cleared) uses the following Header Code 0 definition. This
Header Code 0 definition is compatible with ACR2000/ACR8000
Firmware Versions 1.17.04 and below, and is compatible with all
AcroCut/AcroMill software versions.
Header Code 0
Enable Rapid Move Modes flag disabled—default cleared value:
Data Field Data Type
Description
Bit 0
FVEL
Lockout
Forces
FVEL
to zero for this move
Bit 1
FOV
Lockout
Forces
FOV
to 1.0 for this move
Bit 2
STP
Ramp Activate
Sets
STP
equal to
DEC
, else
STP
0
Bit 3
Code 3 Present
Header contains "Header Code 3"
Bit 4
Velocity Data Present
Packet contains master
VEL
Bit 5
Acceleration Data
Present
Packet contains master
ACC
/
DEC
Bit 6
Counter Dir
Count down if set, else up
Bit 7
Counter Mode
Master move counter enable
The enabled mode for this flag (Secondary Master Flag Bit Index 5
Set) uses the following Header Code 0 definition. This Header Code 0
definition is compatible with ACR2000/ACR8000/ACR8010 Firmware
Versions 1.17.05 and above, and is not compatible with AcroCut/
AcroMill Software Versions 1.15.00 and below. The Move Modes for
this header code are defined following the header code definitions.
Header Code 0
Enable Rapid Move Modes flag enabled—set value:
Data Field Data Type
Description
Bit 0
Move Mode Bit 1
Selects the move mode for this move
along with Header Code 0 Bit 2.
Bit 1
FOV
/
ROV
Lockout
Forces
FOV
or
ROV
to 1.0 for this
move
Bit 2
Move Mode Bit 0
Selects the move mode for this move
along with Header Code Bit 0.
Bit 3
Code 3 Present
Header contains "Header Code 3"
Bit 4
Velocity Data Present
Packet contains master
VEL
Bit 5
Acceleration Data
Present
Packet contains master
ACC
/
DEC
Bit 6
Counter Dir
Count down if set, else up
Bit 7
Counter Mode
Master move counter enable
114 Programmer’s Guide