EN
| User Manual
Annex with technical documentation
48
BSP-MT
1-8/D3
Technical data
Operating Range
Site Selection
frost-free indoor installation in a
non-hazardous environment
Ambient temperature
1,5 to 50 °C (24,7 to 122 °F)
Compressed air inlet temperature
25 to 50 °C (68 to 122 °F)
Max. operating overpressure
16 bar
e
Min. operating pressure
5 bar
e
Medium
Compressed air and gaseous nitrogen
Fluid group
2
Electrical connection
Mains voltage, standard
230 V, 50-60 Hz
Alternative voltage
115 V, 50-60 Hz and 24 V DC
Protection class
IP65
Please note type plate and attached electrical circuit diagram!
Performance details
Type
Volum.
fl ow¹ in
m3/h
Nominal
pipe
size
Upstream
fi lter
1
Upstream
fi lter
2
Downstream
fi lter
Nominal
Press.
in bar
e
Nominal
temp.
°C
BSP-MT 1
8
1/4
AOP010AGFI
AAP010AGFI
AOP010AGMI
16
50
BSP-MT 2
15
1/4
AOP010AGFI
AAP010AGFI
AOP010AGMI
16
50
BSP-MT 3
25
1/4
AOP010AGFI
AAP010AGFI
AOP010AGMI
16
50
BSP-MT 4
35
1/4
AAP010AGFI
AAP010AGFI
AOP010AGMI
16
50
BSP-MT 6
56
1/2
AOP015CGFI
AAP015CGFI
AOP015CGMI
16
50
BSP-MT 7
72
1/2
AAP015CGFI
AAP015CGFI
AOP015CGMI
16
50
BSP-MT 8
86
3/4
AOP020DGFI
AAP020DGFI
AOP020DGFI
16
50
1
. m3/h, relating to 1 bara and 20°C at the compressor suction capacity. Subsequently com-
pressed to 7 bare and 35°C inlet ..temperature to the dryer at 100% relative humidity – for
pressure dewpoints of -25°C and -40°C.
2
In accordance with DIN ISO 228 (BSP-P); alternatively ANSI B 1.20.1 (NPT-F).
Noise emission
Noise level : +3 dB (A)
1
65 – 86 dB(A)
1
.. relative to free fi eld measurement, 1 m surr. fi eld
Drying agent
Chamber 1
100 % drying agent
Chamber 2
100 % molecular sieve
Chamber 3
Down
Middle
Top
33%activated carbon
33% catalyst
33%activated carbon