EN
| User Manual
Shutdown and restart dryer
32
BSP-MT
1-8/D3
After the purifying agent has been replaced
The newly fi lled purifying agent contains minute dust particles that can block the downstream
fi lters. We therefore recommend to complete the following steps before you restart the dryer,
in order to protect your equipment:
Remove the housing base and the fi lter element from the downstream fi lter.
Wear eye protection and dust mask due to increased dust generation!
If the dryer is operated without downstream fi lter, there is a risk of increased
dust generation.
In order to avoid any eye irritations, wear protective goggles!
In order to avoid any dust inhalation, wear dust mask!
Restart the dryer:
Switch on the dryer and pressurise as described in section Open compressed air supply
and switch on dryer, page 22.
The compressed outlet valve must be closed and the downstream fi lter housing must be
open:
Operate the dryer for approx. thirty minutes, blowing the dust particles off from the down-
stream fi lter.
Shut down the dryer:
Close the compressed air inlet valve installed by the owner.
Switch off the dryer by setting the ON/OFF switch to position
0
.
Reassemble the fi lter and commission the dryer (see the operating manual of the fi lter for the
reassembly).
Switch on the dryer and pressurise as described in section Open compressed air supply
and switch on dryer, page 22.
Check that the vessel and the downstream fi lter are leak tight.