EN
| User Manual
Annex with technical documentation
BSP-MT 1-8/D3
49
Dimensions
Please heed to the dimensional drawings and the according table on page 54.
Limits for breathing air
Industrial breathing air
with
brating-
air unit
BSP-MT
Medical air
Europe
UK
USA
Australia
Europe
EN 12021
BS 4275
ANSI/CGA
AS 1715
Ph.European
Carbon
monoxide CO
< 15ppm
< 5ppm
< 10ppm
< 10ppm
< 2ppm
< 5ppm
Carbon
dioxide CO
2
< 500ppm < 500ppm < 1000ppm < 800 ppm
< 150ppm
< 500ppm
humidity H
2
O
< 5 °C *
< 5 °C *
< 10 °F *
<100mg/m3 < 15 ppm**
< 67 ppm
oxygen O
2
21 (±1) %
20 – 23 %
21,5 %
–
20,8–21,1%
20,4 – 21,4 %
Oil quantity
< 0,5 mg/m3 < 0,5 mg/m3 < 0,5 mg/m3
< 1,0 mg/m3 < 0,003mg/m3
< 0,1 mg/m3
odoriferous / aro-
matic substance
Free
free
Free
Free
Free
free
Sufur dioxideSO
2
–
–
–
–
< 0,1 ppm
< 1 ppm
nitrous gases
NO/NO
2
–
–
–
–
< 1 ppm
< 2 ppm
* Pressure dewpoint below inlet temperature ; **Corresponding pressure dewpoint -50°C to
-45°C at 7 bare . .. All values refer to customary concentration levels present in the inlet air.
Replacement and wear part list
Note:
When exchange or replacement parts are ordered, always state the dryer type