HGF Series Service Procedure
30
Figure 82
Figure 81
Figure 80
Figure 79
Install alignment pins
29. Place two alignment pins (11) into
the metering ring (17). See
FIGURE 79.
Install isolation
manifold
30. Stack the isolation manifold (15) (4
plates bonded together) onto the
metering ring (17), aligning the
grooves on the side of the
manifold with the grooves on the
side of the upper cover plate (32)
and the alignment pin holes with
the alignment pins in the metering
ring. The isolation manifold
surface without the recessed slots
must be placed toward the
metering ring. See FIGURE 80.
Install two alignment
pins
31. Install two alignment pins (11) into
the isolation manifold (15). See
FIGURE 81.
Install 1/2 inch springs
32. Place the three 1/2 inch (13 mm)
springs (14) into the spring
pockets of the isolation manifold
(15). See FIGURE 82.
NOTE
NOTE: Two different length springs
are used in the unit. Be sure to use
the 1/2 inch (13 mm) length springs
(14) during this part of the assembly.