13
HGF Series Service Procedure
Figure 17
Figure 16
Figure 15
Figure 14
16. Inspect the springs (14), for
bent or distorted coils. If a
spring is broken or deformed,
all six springs in the unit must
be replaced. See FIGURE 14.
Inspect springs
17. Remove hex drive assembly
(10) from drive link (16). See
FIGURE 15.
Remove hex drive
assembly
18. The pin in the hex drive
assembly (10) should not show
wear and must be firmly
pressed in place. The sides of
the hex and the slot should
not have grooves or scoring. If
the hex drive assembly (10)
shows signs of this type of
wear, it must be replaced.
Inspect hex drive
assembly
19. Remove the two alignment
pins (11) that align the port
manifold (8), valve ring (12)
and isolation manifold (15).
See FIGURE 16.
Remove alignment pins
NOTE: A service kit of nine
alignment pins (11) is available for
servicing the unit.
NOTE
20. Remove the isolation manifold
(15), (four plates bonded together).
See FIGURE 17.
Remove isolation
manifold