1. 

General Safety Instructions                                                                                                 

 

Before putting this cot into operation, it is very important that this User Manual is read carefully. The manual 

contains  important  information  for  safe  and  proper  use  of  the  cot.  Keep  this  manual  handy  for  future 

reference. 

 

All of the functions of this cot should be fully tested by a competent person before the cot is used.   

 

The cot must not be used if faults have been detected that may injure the patient, staff or a third person, or damage 

the cot or the surrounding furniture. 

 

Where necessary, the operating persons are obliged to acquaint the patient lying on the cot with the control functions 

that are designed for use by the patient, and their safe usage. 

 

The operating person is obliged, before using the cot, to be confident of the functionality and safe usage of the cot. 

 

The cot may be used only on even and solid floors. 

 

The cot must never be overloaded. 

Maximum working load - 180 kg (28.3 Stone)

 

If there is a patient on the cot, castors must be locked (with the exception of when travelling with the cot). An unlocked 

cot poses risk of injury to the patient when leaving the cot or when supporting themselves. 

 

The height of the mattress platform must be adjusted according to the height and condition of the patient. 

 

This is a single patient cot; no other people should sit on the cot. 

 

When handling the moving parts of the cot, ensure that the patient, other people or objects do not become trapped. 

 

Before cleaning or maintaining the cot, the mains power cable must be disconnected from the mains. 

 

The cot should not be used where there is a danger of explosion or in the presence of flammable anaesthetics. 

 

When  maintaining  and  cleaning  the  cot  in  the  space  between  the  undercarriage  and  mattress  platform,  the 

adjustment functions on the handset must be locked to avoid unintentional activation of the mattress platform. 

 

The  mains  power  cable  must  be  placed  in  a  way  so  it  does  not  get  wound  around  the  moving  parts  or  trapped 

between them; if the mains power cable is damaged there is a serious danger of injury from electrical current. 

 

Inspections should be made at least once a month for visible wear and tear of all moving parts and cables. 

 

The cot is intended for infants and small children. Ensure that children only have access to the cot under adequate 

supervision. Do not allow children underneath the cot while it is in operation. 

 

2. 

Features                                                                                                                             

 

The drives for the adjustment are electric mechanical linear motors with maintenance free permanent lubrication. 

 

The motors are operated by a handset connected to the main control box via a spiral wound cable. 

 

The motors and handset are isolated from mains voltage (230v) and operated at DC 24v low voltage. 

 

3. 

Installation                                                                                                             

 

The cot should only be assembled by a suitably competent person. The cot is suitable for installation by one person. 

When installing more than five  cots, two people  should be used to complete the installation. They must read and 

fully understand all of the instructions contained in this user manual. Do not attempt to assemble this cot if you are 

unsure about any part of the instructions, or if any damage or defect can be identified. 

 

The fuse in the mains plug should not exceed 5 amps. 

 

The cot should be located on a level flat surface. Do not site the cot on loose carpet, rugs or floor coverings. 

 

The cables from the mains power supply plug to the main control unit  and from the main control unit to the safety 

lock-out box must be positioned clear of the lift mechanism and braked castors to eliminate the danger of shearing 

or crushing the cable. 

Summary of Contents for BUTTERFLY COT

Page 1: ...BUTTERFLY COT User Manual ...

Page 2: ...r sides 6 4 5 The door locking bar option 6 4 6 Connecting the cables 7 4 7 Correct positioning of the cables 7 5 Operating instructions 7 5 1 Operation of the height adjustment and profiling functions 7 5 2 The locking system of the handset 8 5 3 Using the lock out box functions 8 6 Additional Safety information 9 7 Maintenance care and warranty 9 8 Troubleshooting 10 9 Technical data spare parts...

Page 3: ...ot in the space between the undercarriage and mattress platform the adjustment functions on the handset must be locked to avoid unintentional activation of the mattress platform The mains power cable must be placed in a way so it does not get wound around the moving parts or trapped between them if the mains power cable is damaged there is a serious danger of injury from electrical current Inspect...

Page 4: ...ress Support 8 Side Rail 4 door bars 4 Head board Acrylic 9 Safety locking bar optional 4 1 Assembly of the sleeping platform The cot base lifting chassis and mattress support platform will be fully assembled upon delivery IMPORTANT Before operating the cot you must check that all cables have been fitted correctly and that they cannot become trapped damaged and dangerous during use Cot chassis wit...

Page 5: ...l The drop down side rail should be held in the closed position by ensuring that the side is fully raised and that the lower side lugs are located and seated securely in the holder A at each side at the bottom of each corner upright The side rail can be lowered by lifting the lower lugs out of the holders and carefully letting the rail slide down the side runners The side runners will move out sli...

Page 6: ...ting the securing latch upwards whilst opening the door For quick and easy full access to the side the doors can be folded and then fully swung back to each end of the cot 4 5 The door locking bar optional When using either type of the 4 door sides If greater security is required then the optional door locking bar can be installed and used There are pre drilled holes on the upper part of the insid...

Page 7: ...arts of the cot during use This could cause damage to the cables and create a serious safety hazard IMPORTANT Before using the cot and after re locating the lock out box check that all cables have been fitted correctly and that they can not become trapped damaged and dangerous during use 5 Operating instructions IMPORTANT Any person using this cot must read this instruction manual carefully and th...

Page 8: ...perator MUST ensure that Trendelenberg tilting will not have an adverse effect on the patient before using 5 3 Using the Lock out box functions WARNING When moving the lock out box location great care must be taken to ensure that the cable from the main control unit to the safety lock out box is positioned well clear of the lift mechanism and castors to eliminate the danger of shearing or crushing...

Page 9: ...serious or fatal injury When moving the cot with occupant in situ do not push over threshold strips more than 2 cm max height Under no circumstances must the cot be moved by pulling or pushing the side rails either when the cot is occupied or empty Siderails are not designed for this purpose Never exceed the maximum usage period of 6 minutes per hour for the electrically driven cot functions by le...

Page 10: ...lthcare Ltd Motors suddenly have no response or movement 1 Switch off and unplug the mains cable plug it back in and switch on 2 Leave the system in the rest position for approx 20 30 min 3 Contact Park House Healthcare Ltd Permanent or longer sounding warning signal Contact Park House Healthcare Ltd Handset LED lights up in locked state or does not light up in un locked state Contact Park House H...

Page 11: ... Protection The Butterfly Cot offers IP66 Ingress Protection on all electrical components and controls as standard This is a very high level of protection which is completely dustproof and capable of being washed by a jet of water without affecting the electrical operation of the bed WARNING The cot must be disconnected from the mains supply before any kind of washing procedure is undertaken This ...

Page 12: ...service and a network of distribution centres as part of our continued commitment to Customer Care 24 hour care 365 days a year dedicated internal personnel manage specific regions and divisions ensuring one on one personal customer service at all times With distributors in 25 over countries Park House Healthcare are a truly international company and we place important emphasis on providing high l...

Reviews: