Park House Healthcare BUTTERFLY COT User Manual Download Page 12

Park House Healthcare Ltd 

Whitehall 

26 

Business Park, 

Heathfield Lane, Birkenshaw, 

West Yorkshire, BD

11

 

2

HW, UK.

 

Tel:  

0845 0600 333

 

Fax: 

0845 0600 334 

Email: 

[email protected] 

International Tel: 

+44 (0) 1274 475000

 

International Fax: 

+44 (0) 1274 475046

 

International Email: 

[email protected] 

New Corporate Headquarters opened in October 

2006 

The Company

 

 

Founded in 

1984, 

Park House Healthcare Ltd is recognised as one of the leading manufacturers of specialist 

pressure relieving and pressure reducing equipment in the U.K. 

 

Park House Healthcare Ltd has an extensive product portfolio and the facility to customise products to suit 
customer needs whilst offering solutions in pressure care, postural management and moving and handling. 

 

Employing  over 

100

  full  time  staff  at  our 

60,000 

sq.  ft  state  of  the  art  Corporate  Headquarters  in  West    

Yorkshire;  Park  House  Healthcare  are  proud  to  offer  in-house  manufacturing,  a  full  product  audit  and    
decontamination  service  and  a  network  of  distribution  centres  as  part  of  our  continued  commitment  to  

Customer Care.  

 

24 

hour care, 

365 

days a year dedicated internal personnel manage specific regions and divisions     ensuring 

one  on  one  personal  customer  service  at  all  times.  With  distributors  in 

25 

over  countries,  Park  House 

Healthcare are a truly international company and we place important emphasis on providing high levels of 

customer care to ensure we exceed customer expectations at all times. 
 

Additional  support  nationwide  is  available  through  our  service  centres  situated  strategically  around  the 

country. 
 

Park House Healthcare Ltd is a respected member of the British Healthcare Trade Association and has BS 

EN  ISO 

9001 

and  EN 

46002

  accreditation  which  is  the  specific  quality  standard  for  Medical  Devices.  All 

products are CE marked in accordance with the European Directive 

93/42/

EEC.

 

ISO Certificate No: 

8019

 

CE Certificate No: CA

001810

 

Master Indemnity Assurance No: IFA

2433 0451 

CCI 

 

Due to its policy of continued developed and  

improvement, Park House Healthcare Ltd  

reserves the right to amend any details and  
specification without notice. 

 

Rev 

29

NOV

2010 

UM-BUTTERFLY 

Summary of Contents for BUTTERFLY COT

Page 1: ...BUTTERFLY COT User Manual ...

Page 2: ...r sides 6 4 5 The door locking bar option 6 4 6 Connecting the cables 7 4 7 Correct positioning of the cables 7 5 Operating instructions 7 5 1 Operation of the height adjustment and profiling functions 7 5 2 The locking system of the handset 8 5 3 Using the lock out box functions 8 6 Additional Safety information 9 7 Maintenance care and warranty 9 8 Troubleshooting 10 9 Technical data spare parts...

Page 3: ...ot in the space between the undercarriage and mattress platform the adjustment functions on the handset must be locked to avoid unintentional activation of the mattress platform The mains power cable must be placed in a way so it does not get wound around the moving parts or trapped between them if the mains power cable is damaged there is a serious danger of injury from electrical current Inspect...

Page 4: ...ress Support 8 Side Rail 4 door bars 4 Head board Acrylic 9 Safety locking bar optional 4 1 Assembly of the sleeping platform The cot base lifting chassis and mattress support platform will be fully assembled upon delivery IMPORTANT Before operating the cot you must check that all cables have been fitted correctly and that they cannot become trapped damaged and dangerous during use Cot chassis wit...

Page 5: ...l The drop down side rail should be held in the closed position by ensuring that the side is fully raised and that the lower side lugs are located and seated securely in the holder A at each side at the bottom of each corner upright The side rail can be lowered by lifting the lower lugs out of the holders and carefully letting the rail slide down the side runners The side runners will move out sli...

Page 6: ...ting the securing latch upwards whilst opening the door For quick and easy full access to the side the doors can be folded and then fully swung back to each end of the cot 4 5 The door locking bar optional When using either type of the 4 door sides If greater security is required then the optional door locking bar can be installed and used There are pre drilled holes on the upper part of the insid...

Page 7: ...arts of the cot during use This could cause damage to the cables and create a serious safety hazard IMPORTANT Before using the cot and after re locating the lock out box check that all cables have been fitted correctly and that they can not become trapped damaged and dangerous during use 5 Operating instructions IMPORTANT Any person using this cot must read this instruction manual carefully and th...

Page 8: ...perator MUST ensure that Trendelenberg tilting will not have an adverse effect on the patient before using 5 3 Using the Lock out box functions WARNING When moving the lock out box location great care must be taken to ensure that the cable from the main control unit to the safety lock out box is positioned well clear of the lift mechanism and castors to eliminate the danger of shearing or crushing...

Page 9: ...serious or fatal injury When moving the cot with occupant in situ do not push over threshold strips more than 2 cm max height Under no circumstances must the cot be moved by pulling or pushing the side rails either when the cot is occupied or empty Siderails are not designed for this purpose Never exceed the maximum usage period of 6 minutes per hour for the electrically driven cot functions by le...

Page 10: ...lthcare Ltd Motors suddenly have no response or movement 1 Switch off and unplug the mains cable plug it back in and switch on 2 Leave the system in the rest position for approx 20 30 min 3 Contact Park House Healthcare Ltd Permanent or longer sounding warning signal Contact Park House Healthcare Ltd Handset LED lights up in locked state or does not light up in un locked state Contact Park House H...

Page 11: ... Protection The Butterfly Cot offers IP66 Ingress Protection on all electrical components and controls as standard This is a very high level of protection which is completely dustproof and capable of being washed by a jet of water without affecting the electrical operation of the bed WARNING The cot must be disconnected from the mains supply before any kind of washing procedure is undertaken This ...

Page 12: ...service and a network of distribution centres as part of our continued commitment to Customer Care 24 hour care 365 days a year dedicated internal personnel manage specific regions and divisions ensuring one on one personal customer service at all times With distributors in 25 over countries Park House Healthcare are a truly international company and we place important emphasis on providing high l...