To Install the Appliance continued
CONNECTING LEVER AND VALVE LINKAGE
Cut a cross slit in the rubber grommet and feed
the appliance onto the 8mm-gas supply pipe.
Position the restrictor elbow supplied and mark
supply pipe at its cut off length. Remove
appliance, cut pipe to correct length, refit
appliance and make gas connection with
restrictor elbow use 15mm A/F spanner taking
care not to apply any force to the gas control
spindle as above. Ensure the restrictor valve is
opened and its cap replaced tightly.
Taking great care grip the copper protective
sleeve at the end of the gas control spindle (DO
NOT GRIP SPINDLE IN AND OTHER PLACE)
as shown and remove the screw from the end
as shown above.
Ensure the spindle is pushed back inside the
control valve as far as possible. Ensure the bell
crank mechanism is swung up to give easy
access to the gas connection point as shown.
Check for gas soundness. Reconnect the bell
crank mechanism as above ensuring that the
gas control spindle is gripped only over the
protective copper sleeve and no other part of the
spindle as, ensure NO side strain is applied to
the spindle.