11
LT5316 (iss 5) 10/10
FOCUS HE SLIMLINE SC
Installation Instructions
SECTION SIX
Appliance
Data
Category of Appliance
B
AS
Category
I
2H
Gas Type
G20
Gas Pressure: 20 mbar
+
/
-
1.0mbar
Gas Input (Gross) 4.2 kW (Max.)
2.40 kW (Min)
Injectors:
Size 290
Oxy-pilot
9044NG
Data Badge Location: (Behind fret) right hand side of the appliance.
Gas Connection:
8mm OD tube.
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2002 and the
result is 68%. The gross calorific value of the fuel has been used for this efficiency calculation.
GasTec have certified the test data from which it has been calculated. The efficiency value may be
used in the UK Government‟s Standard Assessment Procedure (SAP) for energy rating of dwellings.
PACK CONTENTS
When unpacking the appliance please check the following items are included:
Appliance
(10.5kg)
Owners Manual
Wire fixing kit
Foam seal
Trim (1.5kg)
Fret and ashpan cover (4kg Max)
Refractory Fuel Bed Components (Rear Matrix Front Matrix and Loose Coals.
SECTION SEVEN
Regulations and Warnings
Consumer Protection Information
As manufacturers and suppliers of heating products, we take every care, as far as is reasonably
practicable, that these products are so designed and constructed as to meet the general safety
requirement when properly used and installed. To this end, our products are thoroughly tested and
examined before despatch.
IMPORTANT NOTICE:
Any alteration that is not approved by the appliance manufacturer could
invalidate the approval of the appliance, operation of the warranty and could affect your statutory
rights.