7. Monitoring and Troubleshooting
8700-A2-GB20-40
May 2002
7-17
Viewing G.703 Performance Statistics
G.703 performance statistics allow you to monitor the current status of the G.703
interface when Framed mode is selected.
To view G.703 Performance Statistics, follow this menu selection sequence:
Main Menu
→
Status
→
Performance Statistics
→
G.703 Performance Statistics
The following G.703 Performance Statistics are collected for the selected port:
ES (Errored Seconds): Seconds during which one or more CRC error events
occurred. Maximum value is 900.
UAS (Unavailable Seconds): Seconds during which service is unavailable.
UAS is received at the start of 10 consecutive SES and cleared at the start of
10 seconds with no SES. Maximum value is 900.
SES (Severely Errored Seconds): Seconds during which 805 or more CRC
error events, 16 or more Frame Alignment Signal (FAS) errors, or at least one
Loss of Signal (LOS) or Alarm Indication Signal (AIS) event occurred.
BES (Bursty Errored Seconds): Contains the number of bursty errored
seconds for the current interval. A bursty errored second is any second with
more than one but less than 805 CRC error events (CRC mode) or more than
one but less than 16 FAS errors (non-CRC mode). Maximum value is 900.
CSS (Controlled Slip Seconds): Seconds during which one or more
controlled slips (as defined in TR 54016) occurred.
LOF (Loss of Frame Seconds): Contains the number of seconds that contain
one or more LOF events. Maximum value is 900.
main/status/performance/G.703
Slot: 4 Model: 87xx
Port: 2 G.703 PERFORMANCE STATISTICS
Current Interval Timer: 004 Error Events Counter: 012
-------------------------------------------------------------------------------
--ES-- --UAS-- --SES-- --BES-- --CSS-- -LOF- -Status-
Current Int: 000 000 000 000 000 000 Y
Interval 01 000 000 000 000 000 000 none
Interval 02 000 000 000 000 000 000 none
Interval 03 000 000 000 000 000 000 none
Interval 04 000 000 000 000 000 000 none
Interval 05 000 000 000 000 000 000 none
Interval 06 000 000 000 000 000 000 none
Interval 07 000 000 000 000 000 000 none
Worst Interval: 24 14 14 09 18 12
Tot (valid 96): 00010 00000 00000 00000 0020 0000
-------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
PgUp PgDn ClrStats
Summary of Contents for Hotwire 8779
Page 22: ...2 Using the Asynchronous Terminal Interface 2 10 May 2002 8700 A2 GB20 40...
Page 36: ...3 Initial Startup and Configuration 3 14 May 2002 8700 A2 GB20 40...
Page 44: ...4 Cross Connecting Ports 4 8 May 2002 8700 A2 GB20 40...
Page 52: ...6 Security 6 6 May 2002 8700 A2 GB20 40...
Page 96: ...9 Transferring Firmware and Configurations Using TFTP 9 6 May 2002 8700 A2 GB20 40...
Page 148: ...C Connector Pin Assignments C 4 May 2002 8700 A2 GB20 40...
Page 150: ...D Technical Specifications D 2 May 2002 8700 A2 GB20 40...