MTU-M Maintenance Functions
6-6
7900-A2-GB20-00
March 1998
The following table provides a description of the Operations Parameters Menu.
maxhtu
Valid Values: 2 to 80
Default Setting: 80
Sets the maximum
xTU polling address. xTU addressing counts the number of slots in
the nests, from left to right, top to bottom. The maximum possible
xTU address is the
right-most card in the lowest nest. Refer to
Expansion Nest Numbering Sequence
in
Chapter 2,
MTU-M Installation Procedure, for the multiple nest numbering sequence.
minhtu
Valid Values: 2 to 80
Default Setting: 2
Sets the minimum xTU polling address. Refer to the addressing scheme described for
maxhtu above. Since the MTU-M takes up the first slot in Nest 1 (primary), the
xTU next
to the MTU-M is address #2. Refer to
Expansion Nest Numbering Sequence
in
Chapter 2,
MTu-M Installation Procedure, for the multiple nest numbering sequence.
polling interval
Valid Values: 0 to 255 seconds
Default Setting: 10
Indicates the amount of time the MTU-M waits between successive starts of the polling
cycle. If all of the nest cards can not be polled in this amount of time they may be
skipped.
pollto
Valid Values: 0 to 256 in 256th seconds
Default Setting: 30
Determines polling cycle time for the nonactive circuits in the nest. Nonactive circuits
are those termination units for which a “stoppoll” command has been issued.
alarm
Valid Values: ON, OFF
Default Setting: ON
Determines at time of initial boot-up whether or not alarms are automatically displayed
on the system terminal as they occur.
menu
Valid Values: ON, OFF
Default Setting: ON
Determines at time of initial boot-up whether or not menus are displayed on the system
terminal.
console
Valid Values: 75, 100, 134.5, 150, 300, 600, 1200, 1800, 2000, 2400, 4800,
9600, or 19200
Default Setting: 9600
Sets the baud rate for the system terminal.
Summary of Contents for HOTWIRE 7900
Page 8: ...Contents iv 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 28: ...System Terminal Interface 4 6 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 72: ...Testing 9 12 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 82: ...Glossary GL 4 7900 A2 GB20 00 March 1998 This page intentionally left blank ...