Initial Setup Instructions
3-4
7900-A2-GB20-00
March 1998
Additional Sysconfig Setup Considerations
Depending on the number of nest cards you have, you may need to adjust the
Polling Range, Polling Interval, and Pollto options on the Sysconfig menu:
H
Polling Range – Defines the range of nest cards that the MTU-M will poll.
Adjust the polling range to match the number of total nest cards in your
system starting with slot 2.
H
Polling Interval – Denotes the time the MTU-M waits between successive
starts of the polling cycle. If all of the nest cards can not be polled in this
amount of time they may be skipped.
H
Pollto – Denotes the maximum amount of time, in 256th seconds, that the
MTU-M will wait between the polling of each line card.
For example, if you have 51 nest cards:
1. Set your polling range from 2–51 (slot 1 is the MTU-M).
2. Set initial Pollto to 50/256th seconds (.195 seconds).
3. Set Polling Interval to10 (51 nest cards * .195 seconds = 9.945)
If you find that all of your nest cards are not being polled, you may need to
adjust these values.