Testing
9-3
7900-A2-GB20-00
March 1998
Running a Local Loopback
"
Procedure
To run a local loopback:
1. Type l (for local) at the Select local or remote –> prompt and press Enter.
A screen appears and you are prompted to enter an
xTU id.
2. Enter the number of the
xTU-C you are performing loopback testing on and
press Enter.
The following message appears:
I HTU C/R
HSTATUS TASK MON JAN 1 01:29:05 1997
State change received from DSL 7
HTU-C loopback is ON
Running a Remote Loopback
The MTU-M prevents loopback tests from being run for 1 minute after power is
initially applied to the MTU-M or system reset is performed.
"
Procedure
To run a remote loopback:
1. At the Select local or remote –> prompt, type r (for remote) and press Enter.
A screen appears and you are prompted to enter an
xTU id:
2. Enter the number of the
xTU-C you want to perform loopback testing on and
press Enter.
The following message appears:
I HTU C/R
HSTATUS TASK MON JAN 1 01:35:10 1997
State change received from DSL 7
HTU-R loopback is ON
Ending a Loopback
To stop a local or remote loopback test, repeat the steps in
Running a Local
Loopback
and
Running a Remote Loopback
.
A message stating that the xTU-C/R loopback test is off appears.
Summary of Contents for HOTWIRE 7900
Page 8: ...Contents iv 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 28: ...System Terminal Interface 4 6 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 72: ...Testing 9 12 7900 A2 GB20 00 March 1998 This page intentionally left blank ...
Page 82: ...Glossary GL 4 7900 A2 GB20 00 March 1998 This page intentionally left blank ...