Maintenance and Troubleshooting
5-11
9121-A2-GB20-20
May 1998
Message
What To Do
What It Indicates
Out of Sync
If Monitor Pattern was
selected, it means the test
pattern generator and
receiver have not yet
synchronized. (Path:
main/test/port-
n_ phy or
network_ phy)
No action needed.
If Monitor Pattern was
selected, it means that
5 packets out of 25 are
missing or out of sequence.
(Path: main/test/network,
port-1, port-2, BRI-B1, or
BRI-B2/pvc)
H
Verify that the access unit at
the other end is configured to
Send Pattern.
Correct unit configurations.
H
Check the line’s error rate –
the physical line quality.
Contact service provider.
Password Matching
Error – Re-enter
Password
Password entered in the
Re-enter Password field of
the Administer Logins
screen does not match
what was entered in the
Password field.
H
Try again.
H
Contact your system
administrator to verify your
password.
Set Frame Relay Link
Status to Disable first
Tried to disable the physical
port when the logical link
was up; tried to change
Port Status to Disable while
Link Status was enabled.
1. Change Link Status to
Disable.
2. Retry disabling the port.
Value Out of Range
CIR entered for the DLCI is
a number greater than
64,000, or is a special
character.
Enter a valid CIR ( 0 – 64000 ).
Excess Burst Size entered
for the DLCI is a number
greater than 999,999, or is
a special character.
Enter a valid Excess Burst Size
( 0 – 999999 ).
DLCI Number entered is
less than 16 and greater
than 1007.
Enter a valid number
(16 – 1007 ).
Warning – Config
Changed by
[
SNMP/Autoconfig]
Configuration has been
loaded and is being saved,
but the configuration has
been changed via another
mechanism.
If saving the loaded
configuration is completed,
the configuration changes
made via SNMP or
Auto-Configuration
Shortcuts will be lost.
Cancel the Save command;
select No to the Save Changes?
prompt.