Device Health and Status Messages
Message
Action
Condition
Prt
nnn Disable
Transmitter at port
nnn (01— 06, All) is
disabled.
Use the Control branch’s control option TxCtl to
enable the port.
Prt
nnn Stream Term
Streaming terminal. DTE at port
nnn (01— 06,
All) has its RTS lead turned ON longer than the
predefined time.
Refer to configuration option AntiStream. Verify
DTE operation.
Redun Fan Alarm
Indicates a problem with the fan on the –48 Vdc
Central Office Power Unit.
Check NMS adapter cable connection to
– 48 Vdc power supply cable connections. If
okay, call your sales or service representative.
Redun Pwr Alarm
Indicates a problem with the power on the
– 48 Vdc Central Office Power Unit.
Check NMS adapter cable connection to
– 48 Vdc power supply cable connections. If
okay, call your sales or service representative.
Subnetwrk Alarm
A major alarm was set Off by one of the devices
in your subnetwork.
Check the Subnetwork Health and Status report
and Table E-6.
Sub-normal Speed
The DBM is operating at a dial backup speed
less than the DSU and the DDS network speed.
Set the configuration option DBM Rate(Kbps) to
the DDS network data rate.
Subtree Truncat
Downstream health and status information has
been truncated because of an overflow of the
system limits.
Clear any alarms to decrease the amount of
information reported.