Installing the Model 3550 DSU
2-9
3550-A2-GB20-40
July 1999
Tributary DSU Addressing
Tributary DSU addresses are user-definable, but take
care that their addresses are unique on a multipoint circuit.
If two tributaries are assigned the same address, you will
not be able to communicate with either one.
The control DSU accesses its tributary by specifying
the tributary’s address.
The 6700 Series NMS accesses the DSU via its
network address. To access a tributary DSU, the NMS
first addresses the control, then the tributary. An address
issued from the NMS takes the format of control
channel/control network address/tributary network
address. This is called link-level network addressing.
Figure 2-6 shows an example of DSU and DBM
addressing, as well as link-level network addressing.
Refer to
Chapter 4
to learn how to set the DSU’s
network address.
Figure 2-6. Addressing Example
Summary of Contents for COMSPHERE 3550 Series
Page 4: ...COMSPHERE 3550 Series Data Service Units C July 1999 3550 A2 GB20 40 Notices...
Page 12: ...COMSPHERE 3550 Series Data Service Units vi July 1999 3550 A2 GB20 40...
Page 68: ...COMSPHERE 3550 Series Data Service Units 4 22 July 1999 3550 A2 GB20 40...
Page 98: ...COMSPHERE 3550 Series Data Service Units 5 30 July 1999 3550 A2 GB20 40...
Page 100: ...COMSPHERE 3550 Series Data Service Units A 2 July 1999 3550 A2 GB20 40...
Page 101: ...DSU Menu A 3 3550 A2 GB20 40 July 1999...
Page 108: ...COMSPHERE 3550 Series Data Service Units B 6 July 1999 3550 A2 GB20 40...
Page 122: ...COMSPHERE 3550 Series Data Service Units C 14 July 1999 3550 A2 GB20 40...
Page 129: ...Pin Assignments D 7 3550 A2 GB20 40 July 1999 Figure D 5 EIA 232 D Crossover Cable 4951 035F...
Page 134: ...COMSPHERE 3550 Series Data Service Units E 4 July 1999 3550 A2 GB20 40...