Overview
The Model 3550 DSU is designed for desktop
operation and is delivered ready to connect to the
network. It is configured as a tributary DSU for operation
at 9.6 kbps on a multipoint circuit.
If the unit was ordered with a TDM/Flex installed,
Ports 1 and 2 are configured for 9.6 kbps operation, and
configured as a digital sharing device (DSD). Both ports
are configured for EIA-232 operation, rather than V.35
operation. Refer to the MUX (Port) option set tables in
Chapter 5 to change this configuration on a port-by-port
basis.
Installation consists of the following steps, which
should be performed in the order listed.
•
Physical installation
•
Hardware straps
•
Electrical connection
•
Network diagnostic connection
•
Software configuration
•
DDS network (or LADS) connection
•
Dial (or PSTN) network connection if a DBM is
installed, or if using an external dial backup unit
(DBU)
•
DSU DTE connection
•
Verification testing
Although the Model 3550 DSU is designed for desk or
table-top operation, you can order an ACCULINK
r
3100 Series CSU wall-mount adapter if you want to
mount the DSU on a wall, an equipment shelf, a 19-inch
RS-310-C or 23-inch AT&T DATAPHONE
r
equipment
cabinet. Refer to
Appendix F
to order the adapter.
Before You Begin
Your installation site should be clean, well-lighted,
well-ventilated, and free from environmental extremes.
A dedicated grounded ac outlet that is protected by a
circuit breaker should be installed within 6 feet of the
DSU’s planned location. The outlet should be capable of
supplying 90 to 132 Vac 60 Hz (U.S. and Canada). The
circuit must be capable of supplying a minimum of
2 amperes at 115 Vac. Refer to the
Technical
2
Summary of Contents for COMSPHERE 3550 Series
Page 4: ...COMSPHERE 3550 Series Data Service Units C July 1999 3550 A2 GB20 40 Notices...
Page 12: ...COMSPHERE 3550 Series Data Service Units vi July 1999 3550 A2 GB20 40...
Page 68: ...COMSPHERE 3550 Series Data Service Units 4 22 July 1999 3550 A2 GB20 40...
Page 98: ...COMSPHERE 3550 Series Data Service Units 5 30 July 1999 3550 A2 GB20 40...
Page 100: ...COMSPHERE 3550 Series Data Service Units A 2 July 1999 3550 A2 GB20 40...
Page 101: ...DSU Menu A 3 3550 A2 GB20 40 July 1999...
Page 108: ...COMSPHERE 3550 Series Data Service Units B 6 July 1999 3550 A2 GB20 40...
Page 122: ...COMSPHERE 3550 Series Data Service Units C 14 July 1999 3550 A2 GB20 40...
Page 129: ...Pin Assignments D 7 3550 A2 GB20 40 July 1999 Figure D 5 EIA 232 D Crossover Cable 4951 035F...
Page 134: ...COMSPHERE 3550 Series Data Service Units E 4 July 1999 3550 A2 GB20 40...