Installing the Carrier and Assembly Components
3-15
3000-A2-GA31-D0
July 1999
Alarm Output Connection
To connect the alarm output to an external light or
buzzer:
•
Install the alarm light or buzzer and voltage source
as described in the instructions received with the
light/buzzer and voltage source.
•
Use the two ALARM terminals labeled E1 and E2
at the rear of the carrier to install two external
device leads.
Carrier 6
Carrier 5
Carrier 4
Carrier 3
Carrier 2
Carrier 1
495-12261-02
Customer
Supplied
Voltage
Source
Customer
Supplied
Alarm Light
or Buzzer
To Next
Cabinet
Rear of Cabinet
E4
SGRD
FGRD
E3
E1
E2
ALARM
"
Procedure
1. Use pliers to pull the plastic covers off the E1 and
E2 terminals.
Plastic Cover
496-14656a-01
E2
2. Insert the end of the wire coming from the voltage
source and the end of a wire to be connected to the
next carrier into the E1 terminal. It is not
necessary to strip the wires.
Hollow Tube
Wire Ends
Tube Slot
496-14919b
3. Fit the wires into the slot in the terminal. Replace
the plastic cap on the terminal, fitting the wires
into the matching slot cut lengthwise in the cap.
NOTE
The last carrier to be connected
has one incoming lead for each
terminal.
Cover Slot
496-14919c
Summary of Contents for Compshere 3000 Series
Page 1: ...COMSPHERE 3000 SERIES CARRIER INSTALLATION MANUAL Document No 3000 A2 GA31 D0 July 1999 ...
Page 10: ...COMSPHERE 3000 Series Carrier iv July 1999 3000 A2 GA31 D0 This page intentionally left blank ...
Page 12: ...COMSPHERE 3000 Series Carrier vi July 1999 3000 A2 GA31 D0 ...
Page 52: ...COMSPHERE 3000 Series Carrier 5 8 July 1999 3000 A2 GA31 D0 ...