![Paradyne Compshere 3000 Series Installation Manual Download Page 33](http://html.mh-extra.com/html/paradyne/compshere-3000-series/compshere-3000-series_installation-manual_753734033.webp)
Installing the Carrier and Assembly Components
3-17
3000-A2-GA31-D0
July 1999
The following table describes the SDU’s status
indicators.
Label
Color
Description
OK
green
Normal operation.
Alrm
red
Fault in SDU.
Diag In
yellow
Incoming message from the NMS to
a DSU, DBM, or dial/lease modem.
Diag Out
yellow
Outgoing message to the NMS from
a DSU, DBM, or dial/lease modem.
SDU Modular Jacks and DIP Switches
At the rear of the SDU are four modular jacks:
•
CC IN/DC OUT – 6-pin
•
CC OUT/DC IN – 6-pin
•
FP IN – 8-pin
•
FP OUT – 8-pin
495-14812
SDU Circuit
Card
CC IN/DC OUT
CC OUT/DC IN
FP IN
FP OUT
S2
S1
S2
4
3
2
1
S1
4
3
2
1
ON
OFF
S1 – Protocol
Strap
S2 – Carrier
Address
Below the four modular jacks are two sets of DIP (dual
in-line package) switches labeled S2 and S1.
•
S2: Each device in a cabinet configuration must
have a unique identity. For Model 3611 with
software version 3.nn and earlier, use the top DIP
switch to set the carrier address.
•
S1: Use the bottom DIP switch for CC or
DC operation of the NMS channel.
To set the carrier addresses:
If the device is . . .
Then . . .
Not Model 3611
Enter the address manually
from the front panel.
Model 3611 with software
version of 4.
nn or higher
Enter the address manually
from the front panel.
Model 3611 with software
version of 3.
nn or lower
Use the following procedure
to set the S2 DIP switch for
the carrier address.
"
Procedure
1. Set the carrier address S2-1, S2-2, and S2-3 DIP
switches on the rear of the card, as specified in
Table 3-2
. Note that each carrier in a cabinet must
have a unique address. Use
Table 3-3
to determine
the new carrier’s address.
For a . . .
Then . . .
Single carrier
Leave the S2 switch address
set for Carrier 1 (factory
default).
New cabinet
with an NMS
control channel
Use the address Carrier 1 for
the first carrier, Carrier 2 for
the next, and go up to the
Carrier 7 and 8 addresses for
carriers in the second cabinet
in a single installation.
For the next installation, the
carrier address is numbered 1,
but is on a different control
channel.
Carrier added
to an existing
control channel
Use
Table 3-3
to determine the
new carrier’s address.
Summary of Contents for Compshere 3000 Series
Page 1: ...COMSPHERE 3000 SERIES CARRIER INSTALLATION MANUAL Document No 3000 A2 GA31 D0 July 1999 ...
Page 10: ...COMSPHERE 3000 Series Carrier iv July 1999 3000 A2 GA31 D0 This page intentionally left blank ...
Page 12: ...COMSPHERE 3000 Series Carrier vi July 1999 3000 A2 GA31 D0 ...
Page 52: ...COMSPHERE 3000 Series Carrier 5 8 July 1999 3000 A2 GA31 D0 ...