6. Troubleshooting
6-12
September 2001
7123-A2-GB20-00
Physical Tests
A 7123 DSU/CSU’s physical tests screen for the network interface is shown below.
Main Menu
→
Test
→
[Network Physical Tests/Data Port Physical Tests]
Physical Tests Screen Example
The ResetMon function key at the bottom of the screen only appears when a
Monitor 511 test pattern is Active. Select ResetMon to reset the monitor pattern
error counter.
main/test/network 7123
Device Name: Node A 09/09/2001 06:02
NETWORK 1 PHYSICAL TESTS
Test Command Status Results
Local Loopbacks
Line Loopback: Start Inactive 0:00:00
Payload Loopback: Start Inactive 0:00:00
Remote Loopbacks
Send Line Loopback: Down Send Inactive 0:00:00
Pattern Tests
Send: user-defined 0a0a Stop Active 0:00:00 - Errors 99999+
Monitor: user-defined 0a0a Stop Active 0:00:00 - Errors 99999+
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit