ACCULINK 3163 DSU/CSU
3-10
March 1999
3163-A2-GB20-10
The configuration options are divided into functional
groups.
Appendix C
contains a list of the configuration
options and defaults. These groups are:
•
Port
•
Network Interface
•
Channel
•
General
•
User Interface
•
Alarm
•
Management
The DSU/CSU arrives with two preset factory default
configuration settings. These settings are based on the
following:
•
Factory 1 – ESF framing format with B8ZS line
coding format for the network interface. The data
port is unassigned.
•
Factory 2 – D4 framing format with AMI line
coding format for the network interface. The data
port is unassigned.
If neither of the factory default settings support your
network’s configuration, you can customize the
configuration options to better suit your application.
Use the Configuration (Cnfig) branch of the front panel
menu tree to display or change DSU/CSU configuration
options (see Appendix C,
Configuration Options
).
Displaying/Editing Configuration Options
"
Procedure
To display/edit configuration options:
1. From the top-level menu screen, select Cnfig.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
F1
Load from:
Activ
Cust1
F2
F3
3. Select Edit.
F1
Choose Funct:
Edit
Save
F2
F3
Summary of Contents for 3163
Page 1: ...ACCULINK 3163 DSU CSU USER S GUIDE Document No 3163 A2 GB20 10 March 1999...
Page 6: ...ACCULINK 3163 DSU CSU E March 1999 3163 A2 GB20 10...
Page 22: ...ACCULINK 3163 DSU CSU 2 8 March 1999 3163 A2 GB20 10...
Page 52: ...ACCULINK 3163 DSU CSU 3 30 March 1999 3163 A2 GB20 10...
Page 72: ...ACCULINK 3163 DSU CSU 4 20 March 1999 3163 A2 GB20 10...
Page 74: ...ACCULINK 3163 DSU CSU A 2 March 1999 3163 A2 GB20 10...
Page 140: ...ACCULINK 3163 DSU CSU G 18 March 1999 3163 A2 GB20 10...
Page 142: ...ACCULINK 3163 DSU CSU H 2 March 1999 3163 A2 GB20 10...
Page 150: ...ACCULINK 3163 DSU CSU Glossary 8 March 1999 3163 A2 GB20 10...