Although the password feature is available, it is not
required. If used, it ensures access security before control
is passed to a device connected to a port. The following
procedure is an example only. It shows how to enable the
password for the communication port. Passwords can also
be enabled for the internal modem and for Telnet sessions.
"
Procedure
To establish access security on the communication
port:
1. From the Main Menu screen, select Configuration.
The Load Configuration From screen appears.
2. From the Load Configuration From screen, select
Current.
The Configuration Edit/Display screen appears.
3. From the Configuration Edit/Display screen,
select User Interface.
The User Interface Options screen appears.
4. From the User Interface Options screen, select
Communication Port.
The Communication Port Options screen appears.
5. In the Password Required field, enter Enable
(Figure G-8).
6. Select Save to store this setting in nonvolatile
memory.
The Save Configuration To screen appears.
7. From the Save Configuration To screen, select
Current.
The password itself is set separately. Refer to the
following section,
Setting a Password
.
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
main /config/user/com
Customer ID: Node A
Model: 3163
COMMUNICATION PORT OPTIONS
Port Use:
Terminal
Port Type:
Asynchronous
Data Rate (Kbps):
9.6
Character Length:
8
Parity:
None
Stop Bits:
1
Ignore Control Leads:
Disable
Password Required:
Enable
Inactivity Timeout:
Enable
Disconnect Time (Minutes):
5
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu
MainMenu
Exit
Save
Enable
Password
Figure G-8. Enabling a Password
Summary of Contents for 3163
Page 1: ...ACCULINK 3163 DSU CSU USER S GUIDE Document No 3163 A2 GB20 10 March 1999...
Page 6: ...ACCULINK 3163 DSU CSU E March 1999 3163 A2 GB20 10...
Page 22: ...ACCULINK 3163 DSU CSU 2 8 March 1999 3163 A2 GB20 10...
Page 52: ...ACCULINK 3163 DSU CSU 3 30 March 1999 3163 A2 GB20 10...
Page 72: ...ACCULINK 3163 DSU CSU 4 20 March 1999 3163 A2 GB20 10...
Page 74: ...ACCULINK 3163 DSU CSU A 2 March 1999 3163 A2 GB20 10...
Page 140: ...ACCULINK 3163 DSU CSU G 18 March 1999 3163 A2 GB20 10...
Page 142: ...ACCULINK 3163 DSU CSU H 2 March 1999 3163 A2 GB20 10...
Page 150: ...ACCULINK 3163 DSU CSU Glossary 8 March 1999 3163 A2 GB20 10...