![Paradyne 3162 User Manual Download Page 93](http://html.mh-extra.com/html/paradyne/3162/3162_user-manual_753681093.webp)
Monitoring and Testing
5-29
3162-A2-GB20-40
August 2000
Displaying DSU/CSU Test Status
Use the System and Test Status screen to display the active tests for the
DSU/CSU.
Table 5-12 lists these messages.
"
Procedure
To display test status:
1. From the Main Menu screen, select Status.
2. From the Status screen, select System and Test Status.
Table 5-12.
Test Status Messages
Message
Description
No Test Active
No tests are currently active.
LLB Test Active
The network interface is in Line loopback.
PLB Test Active
The network interface is in Payload loopback.
DLB Test Active
The DTE Drop/Insert (DSX-1) port is in DTE loopback.
RLB Test Active
The DTE Drop/Insert (DSX-1) port is in Repeater
loopback.
DCLB Test Active, Port n
Port n is in a Data Channel loopback.
DTLB Test Active, Port n
Port n is in a Data Terminal loopback.
QRSS Test Active, Network
A QRSS test pattern is being sent on the network
interface.
1–8 Test Active, Network
A 1-in-8 test pattern is being sent on the network
interface.
Mon QRSS Test Active,
Network
A QRSS test pattern is being monitored on the network
interface.
QRSS Test Active, Port n
A QRSS test pattern is being sent to the network on the
channels allocated to port n.
511 Test Active, Port n
A 511 test pattern is being sent to the network on the
channels allocated to port n.
Mon QRSS Test Active,
Port n
A QRSS test pattern is being monitored on the channels
allocated to port n.
Mon 511 Test Active, Port n
A 511 test pattern is being monitored on the channels
allocated to port n.
DLB Test, External Contact
The DTE Drop/Insert (DSX-1) port is being held in DTE
loopback by the external contact.
Lamp Test Active
The Lamp test is currently active.
Summary of Contents for 3162
Page 1: ...ACCULINK 3162 DSU CSU USER S GUIDE Document No 3162 A2 GB20 40 August 2000 ...
Page 12: ...Contents vi 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 16: ...About This Guide x 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 42: ...Operation 3 16 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 64: ...Configuration 4 22 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 94: ...Monitoring and Testing 5 30 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 186: ...Equipment List G 2 3162 A2 GB20 40 August 2000 This page intentionally left blank ...