Table 3-4.
Data Port LEDs
Name
Color
Meaning
DTR
Green
Monitors the state of interchange circuit CD (CCITT 108/1, /2) –
Data Terminal Ready received from the synchronous data DTE.
ON :
DTR is being asserted by the synchronous data
DTE.
OFF :
DTR is not being asserted.
TXD
Yellow
Monitors activity on interchange circuit BA (CCITT 103) –
Transmitted Data. This is the data sent from the synchronous
data DTE to the data port on the DSU/CSU.
ON :
Ones are being received from the synchronous
data DTE.
OFF :
Zeros are being received from the synchronous
data DTE.
CYCLING: Both ones and zeros are being received from the
synchronous data DTE.
RXD
Yellow
Monitors activity on interchange circuit BB (CCITT 104) –
Received Data. This is data sent to the synchronous data DTE
from the data port on the DSU/CSU.
ON :
Ones are being sent to the synchronous data
DTE.
OFF :
Zeros are being sent to the synchronous data
DTE.
CYCLING: Both ones and zeros are being sent to the
synchronous data DTE.
CTS
Yellow
Monitors the state of interchange circuit CB (CCITT 106) –
Clear-to-Send sent to the synchronous data DTE.
ON :
CTS is being asserted by the DSU/CSU.
OFF :
CTS is not being asserted.
RTS
Yellow
Monitors the state of interchange circuit CA (CCITT 105) –
Request-to-Send received from the synchronous data DTE.
ON :
RTS is being asserted by the synchronous data
DTE.
OFF :
RTS is not being asserted.
Summary of Contents for 3162
Page 1: ...ACCULINK 3162 DSU CSU USER S GUIDE Document No 3162 A2 GB20 40 August 2000 ...
Page 12: ...Contents vi 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 16: ...About This Guide x 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 42: ...Operation 3 16 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 64: ...Configuration 4 22 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 94: ...Monitoring and Testing 5 30 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 186: ...Equipment List G 2 3162 A2 GB20 40 August 2000 This page intentionally left blank ...