SNMP MIB Objects
E-13
3162-A2-GB20-40
August 2000
Near End Group – “dsx1SendCode” Object (dsx1ConfigEntry 7)
This object specifies the test patterns/codes being sent over the network
interface. These tests are not supported on the DTE Drop/Insert (DSX-1)
interface. Only the following values are supported by the DSU/CSU.
H
dsx1SendNoCode(1) – Specifies that the interface is sending normal or
looped data. Setting the interface to this value stops an active “send pattern”
test on the interface. This is the only value supported by the DTE Drop/Insert
(DSX-1) interface.
H
dsx1SendLineCode(2) – Specifies that the network interface is sending a
Remote Loopback (Rlpbk) LLBUP code. The code is sent for 10 seconds.
H
dsx1SendResetCode(4) – Specifies that the network interface is sending
Remote Loopback (Rlpbk) LLBDN code. The code is sent for 10 seconds.
H
dsx1SendQRS(5) – Specifies that the network interface is sending a QRSS
test pattern. The pattern is sent until the test is halted (i.e., setting to
dsx1SendNoCode).
H
dsx1SendOtherTestPattern(8) – Specifies that the network interface is
sending a 1-in-8 test pattern. The pattern is sent until the test is halted (i.e.,
setting to dsx1SendNoCode).
Near End Group – “dsx1CircuitIdentifier” Object (dsx1ConfigEntry 8)
This object is only supported on the Net T1 Interface.
Near End Group – “dsx1LoopbackConfig” Object (dsx1ConfigEntry 9)
This object specifies the loopback state of the T1 interfaces. Only the following
values are supported by the DSU/CSU.
H
dsx1NoLoop(1) – The T1 interface is not in a loopback state.
H
dsx1PayloadLoop(2) – Specifies that a Payload Loopback (PLB) is active for
the network interface or a Repeater Loopback (RLB) is active for the DTE
Drop/Insert (DSX-1) interface.
H
dsx1LineLoop(3) – Specifies that a Line Loopback (LLB) is active for the
network interface or a DTE Loopback (DLB) is active for the DTE Drop/Insert
(DSX-1) interface.
Summary of Contents for 3162
Page 1: ...ACCULINK 3162 DSU CSU USER S GUIDE Document No 3162 A2 GB20 40 August 2000 ...
Page 12: ...Contents vi 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 16: ...About This Guide x 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 42: ...Operation 3 16 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 64: ...Configuration 4 22 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 94: ...Monitoring and Testing 5 30 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 186: ...Equipment List G 2 3162 A2 GB20 40 August 2000 This page intentionally left blank ...