Pin Assignments
D-3
3162-A2-GB20-40
August 2000
DTE Drop/Insert Interface
The DTE Drop/Insert (DSX-1) interface connector is a DB15-type socket
connector (Table D-2). For information about using Relay Contact Sense for
external DTE loopback, refer to the DTE LB on Contact configuration option in
DTE Interface Configuration Options
of Appendix C.
The DTE Drop/Insert (DSX-1) cable (Figure D-3) is typically supplied by a DTE
vendor. It is made of shielded twisted-pair wires (22 AWG). The cable connector
is a DB15-type plug connector. Be sure to connect the shield ground only at the
DSU/CSU end to prevent ground loops.
Table D-2.
DTE Drop/Insert (DSX-1 Connector)
Signal
Pin Number
Receiver Tip from DTE
1
Receiver Ring from DTE
9
Transmitter Tip to DTE
3
Transmitter Ring to DTE
11
Relay Contact Sense Return
12
Relay Contact Sense
14
Shield Ground
2,4
Figure D-3.
DTE Drop/Insert (DSX-1) Cable
Summary of Contents for 3162
Page 1: ...ACCULINK 3162 DSU CSU USER S GUIDE Document No 3162 A2 GB20 40 August 2000 ...
Page 12: ...Contents vi 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 16: ...About This Guide x 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 42: ...Operation 3 16 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 64: ...Configuration 4 22 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 94: ...Monitoring and Testing 5 30 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Page 186: ...Equipment List G 2 3162 A2 GB20 40 August 2000 This page intentionally left blank ...