![background image](http://html1.mh-extra.com/html/paradox/uc300/uc300_reference-and-installation-manual_3604808009.webp)
9
UC300 Universal Converter
3.3.2 Hardware Installation 3 options.
Option #1: IP150 Communication Device Only
Figure 4 – Connecting the UC300 with an IP150
1. Clip the UC300 to the system panel box.
2. Clip the IP150 to the system panel box near the UC300.
3. Plug in the UC300 to the IP150 using the IP150 panel port and the UC300 serial port. See Figure 2 for the
proper cable.
4. Connect the Tip and Ring from the UC300 to an outgoing telephone jack.
5. Connect the customer’s control panel Tip and Ring to the UC300 T1 and R1 terminals.
6. Connect the 12Vdc power supply to a supervised power supply or the auxiliary port of the control panel if it
provides 12v supply.
7. Connect an Ethernet cable from the IP150 to the LAN.
Warning:
Connecting the Power Input to an AC/DC power source must be performed only with a safety
approved Limited Power Source (LPS) AC/DC adapter.
Option #2: PCS250/PCS250G Communication Device Only
Figure 5 – Connecting the UC300 with a PCS250/PCS250G
Note:
If you are programming the UC300 using the 307USB disconnect the PCS250/PCS250G, from the UC300
and connect the 307USB to the serial port. You may need to replace the serial cable with the cable in
Figure 3
within the 307USB.
Remove the serial cable from
the UC300 and connect this
cable from the 307USB to the
serial connection of the
UC300