28
Programming Guide
Automatic Report Code List
426 Access door propped open
8E
552 Radio transmitter disabled
B4
427 Access point door status
monitor trouble
8F
Bypasses - 570
428
Access point request to exit
90
570 Zone bypass
B5
429
Access program mode entry
91
571 Fire bypass
B6
430 Access program mode exit
92
572 24Hr. zone bypass
B7
431 Access threat level change
93
573 Burglary bypass
B8
432 Access relay/trigger fail
94
574 Group bypass
B9
433 Access RTE shunt
95
575 Swinger bypass
BA
434 Access DSM shunt
96
576 Access zone shunt
BB
Arming - 440 and 450
577 Access point bypass
BC
441 Armed Stay
97
Test/Misc. - 600
442 Keyswitch armed Stay
98
601 Manual trigger test
BD
450 Exception open/close
99
602 Periodic test report
BE
System Event
Default Contact ID Report Code
Arming with User Code (##)
3 4A1 - Close by user
Auto arming
3 4A3 - Automatic close
Late to close
3 452 - Late to close
No movement
3 452 - Late to close
Partial arming
1 456 - Group bypass
Quick arming
3 4A8 - Quick arm
Arm with PC software
3 4A7 - Remote arm/disarm
Disarm with User Code (##)
1 4A1 - Open by user
Disarm after alarm
*
with User Code (##)
1 4A1 - Open by user
Cancel alarm
**
with User Code (##)
1 4A6 - Cancel by user
Auto-arming cancellation
1 464 - Deferred open/close
Disarm with PC software
1 4A7 - Remote arm/disarm
Disarm after an alarm with PC software
1 4A7 - Remote arm/disarm
Cancel alarm with PC software
1 4A6 - Cancel by user
Cancel paramedic alarm
1 4A6 - Cancel by user
Zone bypassed (##)
1 57A - Zone bypass
Zone alarm (##)
1 13A - Burglary alarm
Fire alarm (##)
1 11A - Fire alarm
Zone alarm restore (##)
3 13A - Burglary alarm restore
Fire alarm restore (##)
3 11A - Fire alarm restore
Panic 1 - emergency
1 12A - Panic alarm
Panic 2 - medical
1 1AA - Medical alarm
Panic 3 - fire
1 115 - Pull station
Recent closing
3 459 - Open/Close
Global zone shutdown
1 575 - Group bypass
Duress alarm
1 121 - Duress
Keypad lockout
1 421 - Access denied
*
An armed system is or was in alarm and was disarmed by a user.
**
A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user.
CID#
Reporting Code
Programming
Value
CID#
Reporting Code
Programming
Value
CID#
Reporting Code
Program-
ming Value
Summary of Contents for Esprit E55
Page 36: ...34 Programming Guide Advanced Technology Zone ATZ Connections...
Page 47: ......