38
Programming Guide
Used for connecting the
IP100
Internet Module.
Also used for In-Field
Firmware upgrade
through a 307USB Direct
Connect Interface. See
Connecting to WinLoad
on page 36 for details.
The
VDMP3
Plug-In Voice Module
must be stacked on top of the
PCS100.
Paradox Memory Key
(PMC-4, PMC5)
Status LED:
• Flash once every second = Normal
• Flashes ON 1 second and OFF 1
second = Any trouble
• Fast flash 6 seconds after power up
= Installer lock enabled
To metallic
enclosure
Ground
clamp
AWG#14 single
conductor solid
copper wire
Cold water
pipe grounding
AUX Power
For AC power connection
information, see AC Power
& Backup Battery
Connections on page 35.
40VA transformer strongly recommended. Exceeding this limit will overload the panel power supply and lead to
complete system shutdown.
The "
BELL
" output
will shutdown if the
current exceeds 3A.
Max. number of keypads = 15 keypads
Max. aux. current = 700 mA
Max. distance of keypad from panel = 76m (250 feet)
Max. total run of wire = 230m (750 feet)
For the keypad’s zone
configurations, refer to the
Installer Quick Menu
. If
EOL is enabled: see section
[706]
option
[2]
. Also refer to
Keypad Zone Connections
on page 33.
Connect to any
Common input.
Refer to
AC Power &
Backup Battery
Connections on page 35.
Refer to Hardware
Connections page 33.
This equipment must be installed and maintained by qualified service personnel only.
For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the E65 Reference & Installation Manual.
E65 PCB Layout
Refer to PGM
Connections
EBUS
port used for GSM reporting
using the
PCS100
GSM
Communicator Module.
Summary of Contents for Esprit E55
Page 36: ...34 Programming Guide Advanced Technology Zone ATZ Connections...
Page 47: ......