background image

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

EN 

Installation Guide 

Fire Keypads and  

Fire Alarm 

Annunciator 

 
 

D1255RB/D1256RB/D1257RB 

 

 

 

Summary of Contents for D1255RB

Page 1: ...EN Installation Guide Fire Keypads and Fire Alarm Annunciator D1255RB D1256RB D1257RB ...

Page 2: ...ontrol Units for Fire protective Signaling Systems UL 1023 Household Burglar Alarm System Units UL 1076 Proprietary Alarm Units UL 1610 Central station Burglar alarm Units UL 1635 Digital Alarm Communicator System Units CA CAN ULC S303 Local Burglar Alarm Units and Systems CAN ULC S304 Signal Receiving Centre and Premise Alarm Control Units ULC ORD C1023 Household Burglar Alarm System Units ULC OR...

Page 3: ...5RB D1256RB and D1257RB Internal Arrangement 5 Figure 2 Releasing the Enclosure Base 6 Figure 3 Lifting the Keypad from the Enclosure Base 6 Figure 4 Removing the Enclosure Base 7 Figure 5 Lifting the Red Cover 7 Figure 6 Removing the Red Cover 7 Figure 7 Removing the Faceplate 7 Figure 8 Setting the Address Switches 8 Figure 9 Address DIP Switches 8 Figure 10 Mounting the Enclosure Base 8 Figure ...

Page 4: ... the keypad it is usually installed in building entrances and areas with unrestricted access Near an exterior door in a hotel or in a business lobby is an ideal mounting location allowing a responding agency or persons evacuating the building to identify quickly the type and location of the emergency from outside without being in danger 2 1 2 D1256RB The D1256RB provides annunciation and system co...

Page 5: ...e signal on a D1255RB Keypad press COMMAND 4 To stop the tone on a D1256RB press the TROUBLE SILENCE key Figure 1 D1255RB D1256RB and D1257RB Internal Arrangement 1 Vacuum fluorescent display VFD 2 Keypad 3 Speaker volume control potentiometer 4 Address DIP switches 5 Status LEDs 6 Wiring harness connector 7 Speaker for sounder The D1257RB does not have a manual method of stopping the trouble buzz...

Page 6: ...1257RB A four wire flying lead is required for the data and power connections between the keypad or annunciator and the control panel The unit includes a wiring harness with four color coded flying leads at one end and a female four pin connector at the other end Refer to Figure 10 and Figure 11 on page 9 to wire the D1255RB D1256RB or D1257RB 3 3 Installation Procedure 1 Power down the control pa...

Page 7: ... 7 Figure 4 Removing the Enclosure Base 1 Enclosure base 2 Top hinges 5 Lift and remove the red cover Figure 5 Lifting the Red Cover Figure 6 Removing the Red Cover 1 Red cover 6 Remove the faceplate Figure 7 Removing the Faceplate 1 Faceplate 7 Set the address switches Refer to Figure 8 Figure 9 and Table 1 ...

Page 8: ...B if power is applied to the control panel 8 Connect the flying leads on the wiring harness Figure 10 to the wiring terminals on the control panel Refer to Table 2 Table 2 Keypad or Annunciator Connections D9412GV2 D7412GV2 Terminal Function Keypad Wire Color Function 32 POWER Red 12 VDC 31 DATA BUS A Yellow Data 30 DATA BUS B Green Data 29 COMMON Black Common Connect with at least 1 5 m 5 ft of 0...

Page 9: ...hinges on the top edge of the unit into place first Figure 12 Installing the Enclosure Base Top 1 Hinges b Press the bottom edge of the unit toward the enclosure base until the tabs snap into the openings in the base Figure 13 Closing the Enclosure Base Bottom 1 Enclosure base 2 Tabs 60 2 F 3478TD Rtqi tco o k pi Tgsw k tgo gpvu For D1255RB and D1257RB programming information refer to the appropri...

Page 10: ...I L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Area is On PRESS ALARM SIL Fire area should remain in the OFF state at all times If the authority level is not programmed correctly and the fire alarm area arms PRESS ALARM SIL shows on the display Pressing the ALARM SILENCE key silences any alarms s and disarms the area The idle text FIRE SYSTEM appears on the display when the area is disarmed Area Not Ready CH...

Page 11: ...GV4 D7412GV4 v2 xx Selecting the corresponding Keypad Type in RPS automatically selects the keypad and functions Refer to the appropriate program entry guide for specific control panel information For the B9512G B8512G and D9412GV4 D7412GV4 v2 xx control panels proceed to section 4 4 1 Figure 16 Example Custom Functions Recommended for UL864 9th Edition CustomFunction Text CustomFunction Keystroke...

Page 12: ...ecuting this function clears the View Memory buffer but does not clear the event out of the event log contained with the control panel 4 4 Function List Figure 17 Example Function List Menu Item Function CC Address1 CC Address2 CC Address3 CC Address4 CC Address5 CC Address6 CC Address7 CC Address8 1 128 Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No 2 129 Yes No Yes No Yes No Yes No Yes ...

Page 13: ...for further explanation of these optional programmable items Ensure that CF 128 through CF 131 are programmed E enabled and not P passcode required Table 3 Function List Description Menu Item Shortcut menu1 Function Description 1 128 ALARM SILENCE 2 129 TROUBLE SILENCE 3 130 DETECTOR RESET 4 131 ANNUNCIATOR RESET 5 9 VIEW MEMORY 6 10 VIEW PT STATUS 7 12 FIRE TEST 8 21 VIEW LOG 9 29 REMOTE PROGRAM ...

Page 14: ..._ __ __ USER 1 Refer to User Passcode Worksheet in the program record sheet for the control panel 4 4 4 Passcode The Passcode section does not apply to D9412GV4 D7412GV4 D7212GV4 v2 xx and later versions A special passcode must be programmed as a valid passcode for the system to work properly This passcode is used in Custom Functions 128 through 131 Use any user number to establish this mandatory ...

Page 15: ...ed keypad functions are in a Menu Function List enabled at an address that coincides with the installed address for a D1256RB Keypad the CC Menu Key Lock prompt is set to No for the D1256RB address Figure 19 Example Keypad Functions Keypad Functions Functions Command E P1 1 Disarm P 2 Master Arm Delay CMD 1 P 3 Master Arm Instant CMD 11 4 Perimeter Instant CMD 2 P 5 Perimeter Delay CMD 3 P 6 Watch...

Page 16: ...P passcode required Refer to Figure 19 Figure 20 Custom Functions Keypad Functions Custom Functions E P 128 Custom Function 128 E 129 Custom Function 129 E 130 Custom Function 130 E 131 Custom Function 131 E 132 Custom Function 133 Custom Function 134 Custom Function 135 Custom Function 136 Custom Function 137 Custom Function 138 Custom Function 139 Custom Function 140 Custom Function 141 Custom F...

Page 17: ...d Idle 104 mA Maximum 225 mA with annunciator lit all 4 Status LEDs on and warning tone on Wiring 4 wire supplies Data In Data Out 12 VDC and Common Maximum data loop resistance is 10 Ω Dimensions H x W x D Base HxW 4 6 in x 8 2 in 11 6 cm x 20 7 cm Cover 4 3 in x 8 12 in x 0 8 in 10 9 cm x 20 6 cm x 2 9 cm Color Red Display 16 character vacuum fluorescent display VSD Each character is a 14 segmen...

Page 18: ...D1255RB D1256RB D1257RB Installation Guide 5 0 Specifications 18 Bosch Security Systems B V 2020 03 F01U011791 02 ...

Page 19: ...D1255RB D1256RB D1257RB Installation Guide Bosch Security Systems Inc 3 20 F01U011791 02 19 ...

Page 20: ... 2020 Bosch Security Systems F01U011791 03 Bosch Security Systems Torenallee 49 5617 BA Eindhoven Netherlands www boschsecurity com ...