Chapter 8:  Specifications 

 

SYSTEM SPECIFICATIONS 

Model Number 

EN450G 

EN600GU 

EN750G 

Topology 

Standby, Simulated Sine Wave 

Maximum Power Capacity 

450VA 

250W 

600VA 

330W 

750VA 

450W 

INPUT

 

Number of Phase 

Single (1Ø 2W +G) 

Nominal Voltage 

120VAC 

Acceptable Input voltage 

0 - 150VAC 

Voltage Range 

95 - 140VAC 

Frequency Limits 

60 Hz, ±6Hz 

Low Voltage Transfer Point 

95V resets to Utility Power at 99V or higher 

High Voltage Transfer Point 

140V resets to Utility Power at 136V or lower 

Input Protection 

Resettable Circuit Breaker 

OUTPUT NON-BATTERY OPERATION

 

Voltage Range 

95 - 140VAC 

Voltage Regulation 

120VAC: -20.8% - +16.7% 

Frequency Range 

60Hz: 54 - 66Hz 

Efficiency (Line Mode) 

>98% (Full Load) 

OUTPUT BATTERY OPERATION

 

Waveform Type 

Simulated Sine Wave 

Nominal Voltage 

120VAC 

Voltage Regulation 

Nominal ±5% (until Low Battery Warning) 

Frequency 

60Hz, ±0.5Hz (unless synchronized to utility) 

Transfer Time 

6 ms Typical 

Overload Capacity 

AC Mode: 105% for 1-minute then shutdown, 
115% Shutdown Immediately 
DC Mode: 105% for 20-seconds then shutdown, 
115% Shutdown Immediately 

Protection 

Over-Current, Short-Circuit Protected, Latching Shutdown 

REGULATORY COMPLIANCE

 

Safety and Approvals 

cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 
107.3:2014/R:2017-10), FCC Class B, CE certified, 
RoHS2 (EU Directive 2011/65/EU & 2015/863/EU) 

 
 

31 

BATTERY SYSTEM 

Battery Type 

Sealed, Non-Spillable, Maintenance Free, 
Value Regulated, Lead Acid

 

Typical Recharge Time 

8-hours to 90% capacity from a full load discharge 

Typical Battery Life 

3 to 5 years.    Environmental factors do affect battery life. 
High temperatures, poor utility power, and frequent, short 
duration discharges have a negative impact on battery life. 

Battery Module Part # 

BM0094 

BM0095 

Runtime: Full Load (minutes) 

2 3 

Runtime: Half Load (minutes) 

10 11 

SURGE PROTECTION AND FILTERING

 

Surge Energy Rating 

1000 J 

Surge Current Capability 

6,500 Amps total (one time 8 to 20us waveform)

 

Surge Response Time 

0 ns (instantaneous) normal mode; <5 ns common mode 

Surge voltage let-through (as 
a percentage of an applied 
ANSI C62.41 Cat. A ±2 kV) 

<5% 

Noise Filter 

>45db normal and common mode EMI/RFI suppression 

Audible Noise at 1 m (3 ft.) 

<45 dBA 

ENVIRONMENTAL

 

Operating Temperature 

0 to 40

C (+32 to +104

F) 

Operating Elevation 

0 to 3000m (0 to +10,000 ft) 

Operating/Storage Humidity 

0 to 95% non-condensing 

Storage Temperature 

-15 to +45

C (+5 to +113

F) 

Storage Elevation 

0 to 15,000m (0 to +50,000 ft) 

PHYSICAL

 

Size - Net 
L X W X H 

12.8 x 5.7 x 4.1” 

324 x 145 x 103 mm 

12.8 x 7.8 x 4.1” 

324 x 198 x 103 mm 

Weight - Net 

7.3 lbs 

3.3 Kgs

 

9.9 lbs 

4.5 Kgs 

Size - Shipping 
L X W X H 

14.9 x 5.8 x 9.0” 

378 x 147 x 227 mm 

15.2 x 5.8 x 10.9” 

386 x 147 x 276 mm 

Weight - Shipping 

8.4 lbs 

3.8 Kgs 

10.8 lbs 

4.9 Kgs 

Power Cord 

5 ft. w/5-15P 

Output Receptacles 

4 - Battery Backup & Surge 
4 – Surge Only 

5 - Battery Backup & Surge 

5 – Surge Only

 

USB CHARGING PORTS EN600GU ONLY

 

Qty / Type / Voltage / Current 

Two (2) / Type ‘A’ / 5Volts / 3Amps max total 

Specifications are subject to change without prior notice. 

Summary of Contents for Minuteman Enspire Series

Page 1: ...ystems Inc 1455 LeMay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000552 R1 Enspire Series UPS EN450G EN600GU EN750G User s M...

Page 2: ...roduction 2 2 Controls and Indicators 8 3 Installation 10 4 Operation 14 5 Obtaining Service 18 6 Troubleshooting 19 7 Replacing the Battery 20 8 Specifications 30 9 Limited product Warranty 32 A1 Dec...

Page 3: ...er ou de les couvrir afin de garantir un fonctionnement fiable de l onduleur et de le prot ger contre la surchauffe N introduisez aucun objet dans les vents ou les ouvertures qui pourrait g ner la ven...

Page 4: ...ING Qualified Service Personnel ONLY must perform the Installation and Servicing of these UPS systems MINUTEMAN accepts no liabilities and is not limited to injury to the Service Personnel or damages...

Page 5: ...a partie responsable de la conformit peuvent annuler le droit de l utilisateur utiliser l quipement 7 NOTE These UPSs are shipped with the batteries disconnected The batteries must be connected before...

Page 6: ...when the UPS is operating in the Battery mode The On Battery Yellow LED will turn on when the UPS is operating in the Battery mode and will turn off when the UPS is operating in the AC normal mode Th...

Page 7: ...read the installation placement and all the cautions before installing the UPS Place the UPS in the final desired location and complete the rest of the installation procedure These UPSs are shipped w...

Page 8: ...the UPS into a two pole three wire grounded receptacle only The utility powered AC wall outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible DO NOT PLUG THE UPS...

Page 9: ...m systems VoIP systems security systems and a variety of electronic equipment from blackouts brownouts over voltages and surges During normal AC operation the UPS will quietly and confidently protect...

Page 10: ...e normal AC mode the alarm will stop the On Battery LED will turn off and the AC normal LED will turn on LOW BATTERY WARNING When the batteries reach the predetermined level the Warning Fault LED will...

Page 11: ...original sales receipt and a brief description of the problem 5 Mark the RMA on the outside of all packages The factory cannot accept any package without the RMA marked on the outside of the package...

Page 12: ...caux pour savoir comment correctement liminer une batterie ou renvoyez la au fournisseur CAUTION The battery system can present a risk of electrical shock These batteries produce enough current to bur...

Page 13: ...DO NOT pull the battery module out by pulling on the battery wires 8 Disconnect the battery positive Red wire FIG 3 9 Disconnect the battery negative Black wire and set the old battery module aside FI...

Page 14: ...la de c t FIG 2 ATTENTION NE retirez PAS la batterie en tirant sur les fils de la batterie 8 D branchez le fil positif de la batterie rouge FIG 3 9 D branchez le fil n gatif de la batterie noir et me...

Page 15: ...e battery module out by pulling on the battery wires 8 Disconnect the battery negative Black wire FIG 3 9 Disconnect the battery positive Red wire and set the old battery module aside Do not short the...

Page 16: ...ers le haut FIG 2 NE retirez PAS la batterie en tirant sur les fils de la batterie 8 D branchez le fil n gatif de la batterie noir FIG 3 9 D branchez le fil positif de la batterie rouge et mettez de c...

Page 17: ...Regulated Lead Acid Typical Recharge Time 8 hours to 90 capacity from a full load discharge Typical Battery Life 3 to 5 years Environmental factors do affect battery life High temperatures poor utilit...

Page 18: ...ESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation of implied warranties therefore the aforesaid limitation s may not ap...

Page 19: ...34 Notes 35 Notes...

Reviews: